CoChat

SwallowNet: Recurrent neural network detects and characterizes eating patterns

Dzung Tri Nguyen, Cohen, Eli, Pourhomayoun, Mohammad, Alshurafa, Nabil · 2017 · 2017 IEEE International Conference on Pervasive Computing and Communications Workshops (PerCom Workshops)
Cited by 25

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Passively detecting and counting the number of swallows in food intake enables accurate detection of eating episodes in free-living participants, and aids in characterizing eating episodes. On average, the more food consumed, the greater the number of swallows; and swallows have been shown to positively correlate with caloric intake. While passive sensing measures have shown promise in recent years, they are yet to be used reliably to detect eating, impeding the development of timely intervention delivery that change poor eating behavior. This paper presents a novel integrated wearable necklace that comprises two piezoelectric sensors vertically positioned around the neck, an inertial motion unit, and long short-term memory (LSTM) neural networks to detect and count swallows. A unique correlation of derivative features creates candidate swallows. To reduce the FPR features are extracted using symmetric and asymmetric windows surrounding each candidate swallow to feed into a Random Forest classifier. Independently, a LSTM network is trained from raw data using automated feature learning methods. In an in-lab study comprising confounding activities of 10 participants, results show a 3.34 RMSE of swallow count using LSTM, and a 76.07% average F-measure of swallows, outperforming the Random Forest classifier. This system thus shows promise in accurately detecting and characterizing eating patterns, enabling passive detection of swallow count, and paving the way for timely interventions to prevent problematic eating.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/percomw.2017.7917596

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 16

  1. 10.2186/prp.6.272 · doi:10.2186/prp.6.272
  2. 10.1371/journal.pone.0070850 · DOI
  3. madgwick, 2010, Automated calibration of an accelerometers, magnetometers and gyroscopes-a feasibility study, Technical Report Technical Report
  4. 10.1109/HIC.2014.7038877 · DOI
  5. 10.1109/TIT.1975.1055330 · DOI · Paper page
  6. hochreiter, 2001, Gradient Flow in Recurrent Nets The Difficulty of Learning Long-term Dependencies
  7. 10.1109/ICASSP.2013.6638947 · DOI · Paper page
  8. 10.1109/CVPR.2015.7298878 · DOI · Paper page
  9. 10.1109/ISWPC.2008.4556181 · DOI
  10. 10.1145/2594368.2594386 · DOI · Paper page
  11. 10.1109/BSN.2014.26 · DOI
  12. päßler, 2012, Food intake monitoring: an acoustical approach to automated food intake activity detection and classification of consumed food, Physiological Measurement, 33, 1073, 10.1088/0967-3334/33/6/1073 · DOI
  13. 10.1016/j.compbiomed.2015.01.005 · DOI
  14. amft, 2006, Methods for detection and classification of normal swallowing from muscle activation and sound, 2006 Pervasive Health Conference and Workshops, 1
  15. zhang, 2016, Machine learning algorithms applied to detect feeding gestures
  16. 10.1109/HIC.2014.7038877 · DOI

Cited by

Metadata

Authors
Nguyen, D. T., Cohen, E., Pourhomayoun, M., & Alshurafa, N.
Venue
2017 IEEE International Conference on Pervasive Computing and Communications Workshops (PerCom Workshops)
Publisher
IEEE
Published
2017-03
Pages
401-406
OpenAlex
W2611410710
Cited by
25
References
5
FWCI
0.89
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.