Virtual synchronous generators
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In electricity grids the frequency of the voltage is stabilized by a combination of the rotational inertia (rotating mass) of synchronous power generators in the grid and a control algorithm acting on the rotational speed of a number of major synchronous power generators. When in future small non-synchronous generation units replace a significant part of the synchronous power generation capacity, the total rotational inertia of the synchronous generators is decreased significantly. This causes large frequency variations that can end up in an unstable grid. A way to stabilize the grid frequency is to add virtual rotational inertia to the distributed generators. A virtual inertia can be attained for any generator by adding a short-term energy storage to it, combined with a suitable control mechanism for its power electronics converter. In this way a generator can behave like a ldquoVirtual Synchronous Generatorrdquo (VSG) during short time intervals, and contribute to stabilization of the grid frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distributed generation: definition, benefits and issues
Pepermans, G., Driesen, J., Haeseldonckx, D., Belmans, R., & D’haeseleer, W. (2005) · Energy Policy · doi:10.1016/j.enpol.2003.10.004 · Cited by 1,592
Self-citationEkanayake, J., & Jenkins, N. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827712 · Cited by 641
Dynamic frequency control with increasing wind generation
Lalor, G., Ritchie, J., Rourke, S., Flynn, D., & O’Malley, M. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2004.1373170 · Cited by 113
Cited by
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Emerging Power Quality Challenges Due to Integration of Renewable Energy Sources
Liang, X. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626253 · Cited by 935
Metadata
- Authors
- Driesen, J., & Visscher, K.
- Venue
- 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century
- Publisher
- IEEE
- Published
- 2008-07
- Pages
- 1-3
- OpenAlex
- W2035221773
- Cited by
- 763
- References
- 3
- FWCI
- 10.80
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.