Data integrity attacks and their impacts on SCADA control system
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Cyber threats for critical infrastructures is an area of growing concern. Data integrity attacks (e.g., manipulating sensor or control signals) on the power system through the SCADA network could have severe effects as it misleads operators into making wrong decisions. However, for an integrity attack to be successful, the malicious data should be within an acceptable range. Hence, only an attacker with intelligence or an understanding of system functionality can cause an effective attack. This paper extends cyber security attack concepts to control systems in an electric power system. Impact on the physical system is estimated by magnitude of load-generation imbalance and frequency deviation after a successful attack on the Automatic Generation Control (AGC) loop. We conduct experiments creating integrity attacks from our attack template on a sample system and evaluate the impact. Our simulation studies show that an integrity attack plan can have severe effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identifying, understanding, and analyzing critical infrastructure interdependencies
(2001) · IEEE Control Systems · doi:10.1109/37.969131 · Cited by 2,851
Vulnerability Assessment of Cybersecurity for SCADA Systems
Ten, C.-W., Liu, C.-C., & Manimaran, G. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2002298 · Cited by 583
Self-citationEstimating a system's mean time-to-compromise
Leversage, D. J., & Byres, E. J. (2008) · IEEE Security & Privacy · doi:10.1109/msp.2008.9 · Cited by 126
Cited by
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
Self-citationCyber security in the Smart Grid: Survey and challenges
Wang, W., & Lu, Z. (2013) · Computer Networks · doi:10.1016/j.comnet.2012.12.017 · Cited by 1,123
Vulnerability Assessment of AC State Estimation With Respect to False Data Injection Cyber-Attacks
Hug, G., & Giampapa, J. A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2195338 · Cited by 595
Model-Based Attack Detection and Mitigation for Automatic Generation Control
Sridhar, S., & Govindarasu, M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2298195 · Cited by 479
Self-citationCyber-Physical Attack-Resilient Wide-Area Monitoring, Protection, and Control for the Power Grid
Ashok, A., Govindarasu, M., & Wang, J. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2686394 · Cited by 278
Metadata
- Authors
- Sridhar, S., & Manimaran, G.
- Venue
- IEEE PES General Meeting
- Publisher
- IEEE
- Published
- 2010-07
- Pages
- 1-6
- OpenAlex
- W2055124586
- Cited by
- 165
- References
- 3
- FWCI
- 10.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.