Electromagnetic generators for power harvesting
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The design of electromagnetic generators that can be integrated within shoe soles is described. In this way, parasitic energy expended by a person when walking can be tapped and used to power portable electronic equipment. Designs are based on discrete permanent magnets and copper wire coils, and it is intended to improve performance by applying micro-fabrication technologies. Detailed descriptions of design and measurements of initial prototype structures are presented, with which RMS voltage levels of over 500 mV have been achieved. Predicted power levels are comparable to those achieved with integrated piezoelectric generators. The design of a second generator structure is introduced. A comparison of the two types of electromagnetic generator structures is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876
Cited by
A Survey of Wearable Devices and Challenges
Seneviratne, S., Hu, Y., Nguyen, T., Lan, G., Khalifa, S., Thilakarathna, K., Hassan, M., & Seneviratne, A. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2731979 · Cited by 821
Smart textiles for personalized healthcare
Libanori, A., Chen, G., Zhao, X., Zhou, Y., & Chen, J. (2022) · Nature Electronics · doi:10.1038/s41928-022-00723-z · Cited by 739
Electromagnetic generator for harvesting energy from human motion
Saha, C. R., O’Donnell, T., Wang, N., & McCloskey, P. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.03.008 · Cited by 608
Energy scavenging for long-term deployable wireless sensor networks
Mathúna, C. Ó., O’Donnell, T., Martinez-Catala, R. V., Rohan, J., & O’Flynn, B. (2008) · Talanta · doi:10.1016/j.talanta.2007.12.021 · Cited by 256
Wearable Biomechanical Energy Harvesting Technologies
Choi, Y.-M., Lee, M., & Jeon, Y. (2017) · Energies · doi:10.3390/en10101483 · Cited by 196
“Some energy harvesters use human joint motion directly for achieving relative movement between a permanent magnet and a coil [33,38].”
BackgroundEnergy scavenging sources for biomedical sensors
Romero, E., Warrington, R. O., & Neuman, M. R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/9/r01 · Cited by 165
A review of walking energy harvesting using piezoelectric materials
Nia, E. M., Zawawi, N. A. W. A., & Singh, B. S. M. (2017) · IOP Conference Series: Materials Science and Engineering · doi:10.1088/1757-899x/291/1/012026 · Cited by 97
“Inertial forces have been used for energy generation either inside shoes [21], within the shoe sole [6, 22], [23] that harvest energy from footfalls or mobile phone chargers integrated in backpacks[24] or phones [25].”
BackgroundBody motion for powering biomedical devices
Romero, E., Warrington, R. O., & Neuman, M. R. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333329 · Cited by 61
Metadata
- Authors
- Duffy, M., & Carroll, D.
- Venue
- 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551)
- Publisher
- IEEE
- Published
- 2005-01-20
- Pages
- 2075-2081
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W1753134022
- Cited by
- 63
- References
- 1
- FWCI
- 11.78
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.