Design considerations for a medium frequency transformer in a line side power conversion system
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Design considerations are presented for a medium frequency transformer in a line side power conversion system for electric railway traction. The system employs soft commutation in order to reduce switching losses and allow for high operating frequency of the transformer. Two different designs are evaluated; The first one is dry insulated and the second one is liquid-immersed. Calculations indicate that a 1 MVA transformer operating at 4 kHz could be realized with an active weight of below 150 kg for both dry and liquid-immersed transformer concepts. The transformers are modeled magnetically, electrically and thermally, and a geometric optimization procedure based on a cost function is applied to achieve an optimum design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135 · cited 2×
“This is addressed in [ 3 ], [4] where several ac-dc converters operating at high frequency are series connected on the ac side and connected in parallel on the dc side.”
Background
Cited by
Hossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Optimized design of medium frequency transformers with high isolation requirements
Ortiz, G., Biela, J., & Kolar, J. W. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5675240 · Cited by 159
Bahmani, M. A., Thiringer, T., & Ortega, H. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292593 · Cited by 71
Novel insulation concept for an MV dry-cast medium-frequency transformer
Gradinger, T. B., Drofenik, U., & Alvarez, S. (2017) · 2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe) · doi:10.23919/epe17ecceeurope.2017.8099006 · Cited by 51
Design and optimization of medium frequency, medium voltage transformers
Shuai, P., & Biela, J. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6634423 · Cited by 43
“Previous research focusing on MFT design has been introduced in [1] [2] [3] for traction applications and in [4] [5] for renewable energy and smart grid applications.”
Varajao, D., Miranda, L. M., Araujo, R. E., & Lopes, J. P. (2016) · IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2016.7793779 · Cited by 17
Metadata
- Authors
- Kjellqvist, T., Norrga, S., & Ostlund, S.
- Venue
- 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551)
- Publisher
- IEEE
- Published
- 2004-11-15
- Pages
- 704-710
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2127341042
- Cited by
- 52
- References
- 1
- FWCI
- 1.66
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.