The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Synchronization Methods for Three Phase Distributed Power Generation Systems. An Overview and Evaluation
Abstract
Nowadays, it is a general trend to increase the electricity production using distributed power generation systems (DPGS) based on renewable energy resources such as wind, sun or hydrogen. Jf these systems are not properly controlled, their connection to the utility network can generate problems on the grid side. Therefore, considerations about power generation, safe running and grid synchronization must be done before connecting these systems to the utility network. This paper is mainly dealing with the grid synchronization issues of distributed systems. An overview of the synchronization methods as well as their major characteristics is given. New solutions to optimize the synchronization methods when running on distorted grid conditions are discussed. Simulation and experimental results are used to evaluate the behavior of the synchronization methods under different kind of grid disturbances such as voltage dips, harmonics and notches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feedback control of dynamic systems
Kahne, S. (1987) · Automatica · doi:10.1016/0005-1098(87)90017-3 · Cited by 3,450
Leonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
Understanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Phase-locked loop techniques. A survey
Hsieh, G.-C., & Hung, J. C. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.544547 · Cited by 784
Synchronisation methods for grid-connected voltage source converters
Svensson, J. (2001) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:20010101 · Cited by 284
Cited by
Comparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F.
- Venue
- IEEE 36th Conference on Power Electronics Specialists, 2005.
- Publisher
- IEEE
- Published
- 2006-10-04
- Pages
- 2474-2481
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2103608196
- Cited by
- 347
- References
- 8
- FWCI
- 26.30
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synchronization Methods for Three Phase Distributed Power Generation Systems. An Overview and Evaluation. https://app.cochat.ai/papers/10.1109/pesc.2005.1581980
- The paper
- Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006). Synchronization Methods for Three Phase Distributed Power Generation Systems. An Overview and Evaluation. IEEE 36th Conference on Power Electronics Specialists, 2005. https://doi.org/10.1109/pesc.2005.1581980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.