The DOI matches its Crossref record.
A new matrix type three-phase four-wire power electronic transformer
Abstract
A new three-phase input, three-phase four-wire output, and with a high-frequency AC link matrix type convertor is discussed. The topology of the conventional matrix convertor is modified with an additional high-frequency transformer for three-phase four-wire electronic power distribution application. The proposed approach accomplishes high output voltage transfer ratio which is more than unity, galvanic isolation between both voltage sources and higher power density by employing a high-frequency transformer into the intermediate stage of the dual bridge matrix convertor. It has the same advantages as the conventional matrix convertor, such as bidirectional power flow capability, controllable input power factor and lower harmonic distortion on both input and output sides. Furthermore, with three dimensional space vector PWM (3D SVPWM) and modified control strategy, the input and output currents may keep low harmonic distortion under unbalanced input voltages or variable three-phase four-wire unbalanced loads. The proposed approach is a competitive solution to the electronic power transformer. Experimental results of a three-phase four-wire 220/380V 5KVA 50Hz electronic power transformer system based on DSP controller are presented and shown to demonstrate the advantages of the proposed system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore, this topology has the capability to reduce the harmonic distortion in both input and output current under unbalanced load conditions by using modified three-dimensional spaced vector PWM (3D SVPWM) [36].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [36]
In the citing paper
“This design offers some benefits such as bidirectional power flow, flexible voltage transfer ratio, controllable input power factor, high power density, and electrical galvanometer isolation.”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [36]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 9
- 2000, IEEE Trial-Use Standard Definitions for the Measurement of Electrical Power Quantities Under Sinusoidal Nonsinusoidal Balanced or Unbalanced Conditions, 18
- 10.1109/IAS.2001.955769 · DOI
- 10.1109/61.891512 · DOI
- 10.1109/PESC.2003.1217754 · DOI
- kiefemdorf, 2000, Power Electronic Transformers for Utility Applications, Proc IEEE-Industrial Applications Soc Conf, 4, 2496
- 10.1109/TPEL.2002.1004239 · DOI
- 10.1109/TPEL.2002.802191 · DOI
- daolian, 2001, Research on Aviation Static Inverter with duty cycle extended high frequency pulse dc link, Transactions of China Electrotechnical Society, 16, 35
- mcmurray, 1970, Power converter circuits having a high-frequency link
Cited by
Sorted by citations
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“Furthermore, this topology has the capability to reduce the harmonic distortion in both input and output current under unbalanced load conditions by using modified three-dimensional spaced vector PWM (3D SVPWM) [36].”
MethodAbu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“Both [21,22] realize flexible power conversion and power factor correction.”
BackgroundInfluential
Metadata
- Authors
- Ai-juan, J., Hang-tian, L., & Shao-long, L.
- Affiliations
- University of Shanghai for Science and Technology (CN)
- Guangdong Telecom, Guangzhou Branch, 128 East Tiyu Road, Guangzhou, China, 510620
- College of Electrical Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, China, 200093
- Venue
- 2006 37th IEEE Power Electronics Specialists Conference
- Publisher
- IEEE
- Published
- 2006-06
- Volume
- 4
- Pages
- 1-6
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W1789796494
- Cited by
- 16
- References
- 0
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2013: 2 · 2012: 1
- FWCI
- 0.53
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Electronics Specialists Conference (PESC) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- matrix converter, solid-state transformer, high-frequency transformer, galvanic isolation, bidirectional power flow, space vector modulation, unbalanced loads, harmonic distortion, power factor control, DSP-based control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review