The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Optimal inverter VAR control in distribution systems with high PV penetration
Abstract
The intent of the study detailed in this paper is to demonstrate the benefits of inverter var control on a fast timescale to mitigate rapid and large voltage fluctuations due to the high penetration of photovoltaic generation and the resulting reverse power flow. Our approach is to formulate the volt/var control as a radial optimal power flow (OPF) problem to minimize line losses and energy consumption, subject to constraints on voltage magnitudes. An efficient solution to the radial OPF problem is presented and used to study the structure of optimal inverter var injection and the net benefits, taking into account the additional cost of inverter losses when operating at non-unity power factor. This paper will illustrate how, depending on the circuit topology and its loading condition, the inverter's optimal reactive power injection is not necessarily monotone with respect to their real power output. The results are demonstrated on a distribution feeder on the Southern California Edison system that has a very light load and a 5 MW photovoltaic (PV) system installed away from the substation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal sizing of capacitors placed on a radial distribution system
Baran, M., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19266 · Cited by 1,505
Inverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331
Self-citationSmart inverter volt/var control functions for high penetration of PV on distribution systems
Smith, J. W., Sunderman, W., Dugan, R., & Seal, B. (2011) · 2011 IEEE/PES Power Systems Conference and Exposition · doi:10.1109/psce.2011.5772598 · Cited by 301
Distribution System Voltage Performance Analysis for High-Penetration PV
Liu, Y., Bebic, J., Kroposki, B., de Bedout, J., & Ren, W. (2008) · 2008 IEEE Energy 2030 Conference · doi:10.1109/energy.2008.4781069 · Cited by 270
Evaluation of Conservation Voltage Reduction (CVR) on a National Level
Schneider, K. P., Fuller, J. C., Tuffner, F. K., & Singh, R. (2010) · doi:10.2172/990131 · Cited by 208
Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics
Liu, E., & Bebic, J. (2008) · doi:10.2172/924648 · Cited by 159
Cited by
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Self-citationAntoniadou-Plytaria, K. E., Kouveliotis-Lysikatos, I. N., Georgilakis, P. S., & Hatziargyriou, N. D. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2679238 · Cited by 545
Li, P., Ji, H., Wang, C., Zhao, J., Song, G., Ding, F., & Wu, J. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2686009 · Cited by 447
Fast Local Voltage Control Under Limited Reactive Power: Optimality and Stability Analysis
Zhu, H., & Liu, H. J. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2504419 · Cited by 409
Mahmud, N., & Zahedi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.030 · Cited by 377
Metadata
- Authors
- Farivar, M., Neal, R., Clarke, C., & Low, S.
- Venue
- 2012 IEEE Power and Energy Society General Meeting
- Publisher
- IEEE
- Published
- 2012-07
- Pages
- 1-7
- OpenAlex
- W1995874947
- Cited by
- 345
- References
- 6
- FWCI
- 29.48
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal inverter VAR control in distribution systems with high PV penetration. https://app.cochat.ai/papers/10.1109/pesgm.2012.6345736
- The paper
- Farivar, M., Neal, R., Clarke, C., & Low, S. (2012). Optimal inverter VAR control in distribution systems with high PV penetration. 2012 IEEE Power and Energy Society General Meeting. https://doi.org/10.1109/pesgm.2012.6345736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.