Grid-Forming Droop Control of a Modular Multilevel Converter in Laboratory
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Electrical power systems are currently facing a steady increase of converter-based generation and a loss of conventional power plants. In order to compensate the decrease of inertia and to retain grid restoration capability, the converters have to operate in grid-forming mode and act as a voltage source. While the grid-forming concept itself is applicable to many converter types, the challenge for Modular Multilevel Converters (MMC), in which power input and power output are decoupled, is the voltage control of the submodule capacitors. This paper deals with the laboratory implementation of a grid-forming MMC with submodule-integrated as well as DC-bus-connected batteries. The objective was to enhance the established grid-feeding control, which decouples power input and power output of the converter, towards grid-forming control and operation. Therefore, the inner current controllers and outer energy balancing controllers were extended by voltage and PQ droop controllers and virtual impedances. The two main features shown in the test cases were instantaneous active power support and parallel operation of the grid-forming MMC with other voltage sources, i.e. with the grid and with another grid-forming converter. Load switching in islanded mode proved the ability to provide active power instantaneously while maintaining the voltage balance of the submodule capacitors. From these results, important functions of a grid-forming MMC can be derived for future power systems, e.g. instantaneous frequency support and inertia emulation or grid restoration capability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Virtual Impedance Current Limiting for Inverters in Microgrids With Synchronous Generators
Paquette, A. D., & Divan, D. M. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2345877 · Cited by 580
Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267 · cited 3×
“The focus is instantaneous active power support and parallel operation of the grid-forming MMC with other voltage sources, whereas in [7] the MMC is operating as the only voltage source.”
BackgroundVoltage unbalance and harmonics compensation for islanded microgrid inverters
Liu, Q., Tao, Y., Liu, X., Deng, Y., & He, X. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2013.0410 · Cited by 123
Small-Signal Stability Analysis of Offshore AC Network Having Multiple VSC-HVDC Systems
Raza, M., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2725982 · Cited by 90
Modeling and current control of modular multilevel converters considering actuator and sensor delays
Munch, P., Liu, S., & Dommaschk, M. (2009) · 2009 35th Annual Conference of IEEE Industrial Electronics · doi:10.1109/iecon.2009.5414756 · Cited by 48
Laudahn, S., Seidel, J., Engel, B., Bülo, T., & Premm, D. (2016) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2016.7527020 · Cited by 25
Control of modular multilevel converters as virtual synchronous machines
Lv, Z., & Zhong, Q. (2017) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2017.8274551 · Cited by 23
Energy balancing in the modular multilevel converter under unbalanced grid conditions
Schroeder, M., Mahr, F., Jaeger, J., & Haensel, S. (2017) · European Conference on Power Electronics and Applications · doi:10.23919/epe17ecceeurope.2017.8099247 · Cited by 14
Self-citationA novel control strategy for the interlinking converter in hybrid microgrid
Alrajhi, H. K., El‐Shatshat, R., & Radwan, A. A. A. (2017) · IEEE Power & Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2017.8274192 · Cited by 13
Measurement results of a modular energy storage system unevenly equipped with lithium-ion batteries
Schroeder, M., Schmitt, S., Henninger, S., Jaeger, J., Rubenbauer, H., & Reimann, O. (2015) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2015.7309438 · Cited by 12
Self-citation
Research works printed but not linked: 1
- duckwitz, 2017, Operational Behavior of the Virtual Synchronous Machine, 12 ETG/GMA-Fachtagung „Netzregelung und Systemführung"
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“MMC performs active power support as well as parallel operation with other voltage sources and islanding operation [86].”
BackgroundThe Role of the Internal Energy in MMCs Operating in Grid-Forming Mode
Sánchez‐Sánchez, E., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2961774 · Cited by 69
“In [16], a classic grid-forming control scheme together with full energy-based control is implemented in an MMC and successfully tested in the laboratory, discussing the implications of having a storage system in the dc side or inside the MMC submodules.”
MethodAdvanced classification of converter control concepts for integration in electrical power systems
Henninger, S., & Jaeger, J. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106210 · Cited by 29
Self-citationLiu, W., Wang, R., Kerekes, T., Dragičević, T., & Teodorescu, R. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3293431 · Cited by 10
“In [18], the droop function of GFM-MMC is successfully implemented with full energy-based control in the laboratory, outlining the implications of having a storage capability in the SM units on the power transfer decoupling”
MethodA Zero Harmonic Distortion Grid-Forming Converter for Islanded Microgrids
Ramos, G. V., Parreiras, T. M., Brandão, D. A. D. L., Silva, S. M., & Filho, B. J. C. (2023) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias54024.2023.10406502 · Cited by 7
Ramos, G. V., Parreiras, T. M., & Filho, B. J. C. (2023) · IEEE Brazilian Power Electronics Conference and Southern Power Electronics Conference · doi:10.1109/spec56436.2023.10407128 · Cited by 6
“In literature a wide range of grid-forming converters applications is based on 2/3-level Voltage Source Converters (VSC) [11] and transformeless topologies such as Modular Multilevel Converters (MMC) [12]–[14].”
BackgroundA Zero Harmonic Distortion Grid-Forming Converter for Medium Voltage Islanded Microgrids
Ramos, G. V., Brandão, D. A. D. L., Parreiras, T. M., Silva, S. M., & Filho, B. J. C. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3462913 · Cited by 5
Contribution to the classification of power electronic assets in converter-dominated grids
Vahle, D., & Staudt, V. (2020) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam48782.2020.9161930 · Cited by 4
Ramos, G. V., Parreiras, T. M., & Filho, B. J. C. (2024) · Eletrônica de Potência · doi:10.18618/rep.e202441 · Cited by 3
“In literature a wide range of grid-forming converters applications is based on 2/3-level Voltage Source Converters (VSC) [11] and transformeless topologies such as Modular Multilevel Converters (MMC) [12]–[14].”
BackgroundFrequency-Watt and Volt-Var Control by Self-commutated Converter Connected Controllable DC Load
Nakamura, Y., Aoki, M., Kado, Y., & Iki, H. (2022) · IEEJ Transactions on Power and Energy · doi:10.1541/ieejpes.142.106 · Cited by 3
Dynamic Current-Limitation Strategy of Grid-Forming Inverters Based on SR Latches
Zhang, H., Ma, J., & Li, X. (2024) · Electronics · doi:10.3390/electronics13173432 · Cited by 4
Schulze, W., Nowak, T., Pawlowski, P., Suriyah, M., & Leibfried, T. (2020) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec49904.2020.9209851 · Cited by 2
“In other experimental studies, power electronic grid emulations are used for this purpose [7].”
BackgroundRamos, G. V., Parreiras, T. M., & Filho, B. J. C. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc61721.2024.10726351 · Cited by 2
“In literature a wide range of grid-forming converters applications is based on 2/3-level Voltage Source Converters (VSCs) [11] and transformeless topologies such as Modular Multilevel Converters (MMCs) [12]–[14].”
BackgroundSwitching Control of Off-Grid/Grid-Connected Modes in Grid-forming PV-Storage Systems Based on VSG
Wang, Y., Zhou, Q., Xiong, W., Yu, J., & Miao, M. (2025) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon58223.2025.11221565 · Cited by 1
“At present, the grid-forming control approaches are mainly included as the droop control [4], virtual synchronous generator (VSG) control [5], synchronous power control [6], virtual oscillator control [7], and so on.”
DC-Side Impedance Modeling and Stability Assessment in Grid-Forming Modular Multilevel Converters
Nahalparvari, M., Asoodar, M., Norrga, S., & Nee, H. (2023) · European Conference on Power Electronics and Applications · doi:10.23919/epe23ecceeurope58414.2023.10264662 · Cited by 1
Herath, N., & Filizadeh, S. (2019) · IEEE International Conference on Industrial and Information Systems (ICIIS) · doi:10.1109/iciis47346.2019.9063287 · Cited by 1
“Other authors have extensively presented various novel control techniques to integrate energy storage, renewable energy sources as well as to provide ancillary services using this converter [6], [8][11].”
BackgroundViatkin, A. (2023) · Springer theses · doi:10.1007/978-3-031-24712-5_1
Advanced Control Strategy for Improving Stability in Grid-Forming-Based Modular Multilevel Converter
Liu, W. (2024) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau715846611
Coordinated Control Strategy of Two-Stage Converters in Grid-Forming PV Power Generation System
Guo, M., Tong, X., Xiang, Y., & Zhang, X. (2025) · Lecture notes in electrical engineering · doi:10.1007/978-981-96-2042-5_22
Grid-Forming Energy Storage control strategy for Black-Start scenario of new energy power system
Ma, J., Sun, J., Xiang, Y., Lu, C., Zhou, Z., & Huang, Z. (2025) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei268505.2025.11425469
“Common grid-forming control strategies currently in widespread use include CVCF control, droop control [8], improved droop control, VSG control [9]–[13], and matching control.”
Metadata
- Authors
- Henninger, S., Schroeder, M., & Jaeger, J.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Venue
- 2018 IEEE Power & Energy Society General Meeting (PESGM)
- Publisher
- IEEE
- Published
- 2018-08
- Pages
- 1-5
- ISSN
- 1932-5517 (ISSN-L)
- OpenAlex
- W2906434075
- Cited by
- 20
- References
- 13
- Citations by year
- 2025: 3 · 2024: 5 · 2023: 5 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 2
- FWCI
- 2.39
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Engineering Society General Meeting (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- grid-forming control, modular multilevel converter, droop control, submodule capacitor voltage balancing, virtual impedance, battery energy storage, islanded operation, load switching, active power support, inertia emulation, grid restoration, low-inertia power systems, converter-based generation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.