CoChat

Grid-Forming Droop Control of a Modular Multilevel Converter in Laboratory

Henninger, Stefan, Schroeder, Markus, Jaeger, Johann · 2018 · 2018 IEEE Power & Energy Society General Meeting (PESGM)

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Electrical power systems are currently facing a steady increase of converter-based generation and a loss of conventional power plants. In order to compensate the decrease of inertia and to retain grid restoration capability, the converters have to operate in grid-forming mode and act as a voltage source. While the grid-forming concept itself is applicable to many converter types, the challenge for Modular Multilevel Converters (MMC), in which power input and power output are decoupled, is the voltage control of the submodule capacitors. This paper deals with the laboratory implementation of a grid-forming MMC with submodule-integrated as well as DC-bus-connected batteries. The objective was to enhance the established grid-feeding control, which decouples power input and power output of the converter, towards grid-forming control and operation. Therefore, the inner current controllers and outer energy balancing controllers were extended by voltage and PQ droop controllers and virtual impedances. The two main features shown in the test cases were instantaneous active power support and parallel operation of the grid-forming MMC with other voltage sources, i.e. with the grid and with another grid-forming converter. Load switching in islanded mode proved the ability to provide active power instantaneously while maintaining the voltage balance of the submodule capacitors. From these results, important functions of a grid-forming MMC can be derived for future power systems, e.g. instantaneous frequency support and inertia emulation or grid restoration capability.

Overview

Integrity signals

Registry

Crossref · 10.1109/pesgm.2018.8586205

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 1

  1. duckwitz, 2017, Operational Behavior of the Virtual Synchronous Machine, 12 ETG/GMA-Fachtagung „Netzregelung und Systemführung"

Cited by

See all 20

Metadata

Authors
Henninger, S., Schroeder, M., & Jaeger, J.
Affiliations
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
Venue
2018 IEEE Power & Energy Society General Meeting (PESGM)
Publisher
IEEE
Published
2018-08
Pages
1-5
ISSN
1932-5517 (ISSN-L)
OpenAlex
W2906434075
Cited by
20
References
13
Citations by year
2025: 3 · 2024: 5 · 2023: 5 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 2
FWCI
2.39
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Power Engineering Society General Meeting (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
grid-forming control, modular multilevel converter, droop control, submodule capacitor voltage balancing, virtual impedance, battery energy storage, islanded operation, load switching, active power support, inertia emulation, grid restoration, low-inertia power systems, converter-based generation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.