EV Hosting Capacity Analysis on Distribution Grids
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The increasing trend in electric vehicle (EV) adoption can cause challenges to traditional electric grid operations if utilities are not equipped with tools and methods to effectively manage these fleets. Growing EV charging loads will alter the magnitude and duration of conventional peaks in demand profiles and even significantly shift them, potentially causing operational violations in the distribution grid. This paper presents the development and results of an EV hosting capacity tool to quantify the impacts of injecting large numbers of EV charging loads and to determine the available capacity of existing distribution feeders to continue providing reliable and affordable grid operations. Tools like the hosting capacity analysis would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies to manage these loads, such as peak pricing and smart charging. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging options.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coordinated Charging of Plug-In Hybrid Electric Vehicles to Minimize Distribution System Losses
Sortomme, E., Hindi, M. M., MacPherson, S. D. J., & Venkata, S. S. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2090913 · Cited by 1,155 · cited 1×
“Controlled or coordinated charging of EVs could be one solution for grid operators to address these network issues [2].”
BackgroundState-of-the-art of hosting capacity in modern power systems with distributed generation
Ismael, S. M., Abdel Aleem, S. H. E., Abdelaziz, A. Y., & Zobaa, A. F. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.07.008 · Cited by 599 · cited 1×
“words, hosting new distributed generators or EV loads can be accommodated in some locations to varying extents [4].”
BackgroundBollen, M., & Rönnberg, S. (2017) · Energies · doi:10.3390/en10091325 · Cited by 169 · cited 1×
“static parameter can be defined as the amount of new production/consumption that can be connected to the grid without risking reliability or voltage quality for other customers [3].”
Background
Cited by
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Hosting Capacity of an Australian Low-Voltage Distribution Network for Electric Vehicle Adoption
Then, J., Agalgaonkar, A. P., & Muttaqi, K. M. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3337068 · Cited by 20
Umoh, V., Adebiyi, A., & Moloi, K. (2023) · Eng · doi:10.3390/eng4030111 · Cited by 12
Metadata
- Authors
- Paudyal, P., Ghosh, S., Veda, S., Tiwari, D., & Desai, J.
- Venue
- 2021 IEEE Power & Energy Society General Meeting (PESGM)
- Publisher
- IEEE
- Published
- 2021-07-26
- Pages
- 1-5
- OpenAlex
- W4205782132
- Cited by
- 52
- References
- 3
- FWCI
- 13.50
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EV Hosting Capacity Analysis on Distribution Grids. https://app.cochat.ai/papers/10.1109/pesgm46819.2021.9638170
- The paper
- Paudyal, P., Ghosh, S., Veda, S., Tiwari, D., & Desai, J. (2021). EV Hosting Capacity Analysis on Distribution Grids. 2021 IEEE Power & Energy Society General Meeting (PESGM). https://doi.org/10.1109/pesgm46819.2021.9638170
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.