Super-capacitors for implantable medical devices with wireless power transmission
Abstract
Patients using implantable devices with wireless power transmission (such as inductive telemetry) as the energy source are required to carry external hardware and antennas on their body continuously during the monitoring period. This discomfort can be reduced by integrating tiny super-capacitors as an energy source for the device. The external wireless telemetry unit used to activate and interrogate the implantable device charges the super capacitors integrated on it. When the wireless telemetry unit is removed, the super capacitor powers the implantable device. This paper shows the benefits of integrating super capacitors onto an existing pressure sensing medical implant that utilises an inductive telemetry link. Test results show that the implant can be powered for a full day using an 88 mF super capacitor. This super capacitor can be fully charged using the inductive telemetry link at a wireless distance of 20 cm in 81 seconds.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Transmitted energy is typically stored in internal rechargeable batteries or capacitors, even soft ones, for sustained use, although some systems may offer continuous power supply directly to capacitors.
“The transmitted energy is typically stored in internal rechargeable batteries or capacitors (Mendoza-Ponce et al., 2018), even soft ones (Li et al., 2019; Sheng et al., 2021) for sustained use, although some systems may offer continuous power supply directly to capacitors.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Mendoza-Ponce et al., 2018
Cites
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322 · see citing works
Measurement of Supercapacitor Fractional-Order Model Parameters From Voltage-Excited Step Response
Freeborn, T. J., Maundy, B., & Elwakil, A. S. (2013) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2013.2271433 · Cited by 196 · see citing works
Long term, implantable blood pressure monitoring systems
Potkay, J. A. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9146-3 · Cited by 113 · see citing works
Ellozy, S. H., Carroccio, A., Lookstein, R., Minor, M. E., Sheahan, C. M., Juta, J., Cha, A., Valenzuela, R. G., Addis, M. D., Jacobs, T. S., et al. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.06.027 · Cited by 109 · see citing works
Optimal Transmission Frequency for Ultralow-Power Short-Range Radio Links
Yates, D. C., Holmes, A. S., & Burdett, A. J. (2004) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2004.830696 · Cited by 87 · see citing works
Micromachined endovascularly-implantable wireless aneurysm pressure sensors: from concept to clinic
Allen, M. G. (2005) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2005.1496410 · Cited by 70 · see citing works
Further experimental evidence of the fractional-order energy equation in supercapacitors
Elwakil, A. S., Allagui, A., Freeborn, T. J., & Maundy, B. (2017) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2017.03.027 · Cited by 46 · see citing works
SOLARCAP: Super capacitor buffering of solar energy for self-sustainable field systems
Fahad, A., Soyata, T., Wang, T., Gaurav Sharma, A., Heinzelman, W., & Shen, K. (2012) · IEEE International SOC Conference (SOCC) · doi:10.1109/socc.2012.6398354 · Cited by 30 · see citing works
Springer, L., Schlierf, R., Pfeffer, J.-G., Mahnken, A. H., Schnakenberg, U., & Schmitz‐Rode, T. (2007) · European Radiology · doi:10.1007/s00330-007-0583-4 · Cited by 29 · see citing works
Melo-Thomas, L., Engelhardt, K.-A., Thomas, U., Hoehl, D., Thomas, S., Wöhr, M., Werner, B., Bremmer, F., & Schwarting, R. K. W. (2017) · Journal of Visualized Experiments · doi:10.3791/56299 · Cited by 12 · see citing works
Wireless Blood Pressure Measurement Implant Electronics for Integration in a Stent Graft
John, B. B., Ranjan, R., Spink, C., Schroeder, D., Koops, A., Adam, G., & Krautschneider, W. H. (2016) · Biomedical Engineering · doi:10.2316/p.2016.832-042 · Cited by 2 · see citing works
Self-citationReceiver for inductively coupled communication with an implantable sensor
Moss, C., Sass, W., & Mueller, J. (2011) · International Symposium on Applied Sciences in Biomedical and Communication Technologies · doi:10.1145/2093698.2093729 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 256 · see citing works
Supercapacitors: A promising solution for sustainable energy storage and diverse applications
Gopi, C. V. V. M., Alzahmi, S., Narayanaswamy, V., Vinodh, R., Issa, B. A., & Obaidat, I. M. (2025) · Journal of Energy Storage · doi:10.1016/j.est.2025.115729 · Cited by 194 · see citing works
Yu, M., Peng, Y., Wang, X., & Ran, F. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202301877 · Cited by 156 · see citing works
Morsada, Z., Hossain, M. M., Islam, M. T., Mobin, M. A. M., & Saha, S. (2021) · Applied Materials Today · doi:10.1016/j.apmt.2021.101257 · Cited by 77 · see citing works
Aftab, J., Ali, A., Mehmood, S., Aftab, A., Ahmad, I., Bhopal, M. F., Hussain, M., Shah, Z. U., Shah, A., Padhiar, M. A., et al. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.109324 · Cited by 29 · see citing works
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21 · see citing works
Biosupercapacitors with minimized Self-Discharge
Dey, T., Dial, A., Corridon, P. R., & Dutta, S. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.144101 · Cited by 14 · see citing works
Fobiri, G. K., Eghan, B., Seidu, R. K., & Tawiah, B. (2025) · Essential Chem · doi:10.1080/28378083.2025.2493111 · Cited by 11 · see citing works
Lu, Y., & Hong, S.-H. (2023) · Materials · doi:10.3390/ma16165576 · Cited by 7 · see citing works
Guida, R., & Melodia, T. (2025) · Ad hoc networks · doi:10.1016/j.adhoc.2024.103748 · Cited by 8 · see citing works
MXene nanosheets decorated with MoP nanoparticles as high-performance supercapacitor material
Thamir, K. H., Al-Khazragie, Z. K., Rejab, Z. A., Al-Ashoor, S. Z., Abbood, A. A., Abbood, H. A., Abdullaeva, B. S., Rusho, M. A., Diab, M. A., Arabi, A. I. A., et al. (2025) · Diamond and Related Materials · doi:10.1016/j.diamond.2025.112781 · Cited by 4 · see citing works
Fadhel, Y. B., Trigui, A., Rahmani, S., & Al‐Haddad, K. (2021) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-030-71221-1_3 · Cited by 4 · see citing works
A 1.9 nW Timer and Clock Generation Unit for Low Data-Rate Implantable Medical Devices
Ponce, P. M., Sayed, G. M., Saleh, L. A., Krautschneider, W. H., & Kuhl, M. (2020) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas45839.2020.9068949 · Cited by 3 · see citing works
Self-citationWireless Power Transmission System via Magnetic Resonance Coupling Platform
Ye, Y., Peng, C., Wang, Y., Chen, J., Liao, J.-C., Ma, T., Liang, Y., & Zhou, M. (2019) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2019.8816391 · Cited by 3 · see citing works
Coil Arrangement Optimization to Improve Efficiency of Multiple-Relay Wireless Power Transfer System
Wu, N., Xiao, J., Yin, L., Chen, S., & Wu, X. (2021) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee53554.2021.9676931 · Cited by 3 · see citing works
Ponce, P. M., Sayed, G. M., Saleh, L. A., Krautschneider, W. H., & Kuhl, M. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919042 · Cited by 3 · see citing works
Self-citationEffect of Supercapacitor on Power Supply for Rechargeable Implanted Medical Devices
Rita, A. A., Misra, S., Ahuja, R., & Oluranti, J. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-15-8297-4_11 · Cited by 2 · see citing works
An Electronic Osteosynthesis Implant for Continuous Load Monitoring using a Strain Gauge
Adam, C., Barth, T., Munch, M., Seide, K., & Krautschncider, W. H. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644959 · Cited by 2 · see citing works
Advancements in Resonant Inductive Coupling for the Wireless Powering of Active Implants
Fadhel, Y. B., Rahmani, S., & Al‐Haddad, K. (2026) · Springer eBooks · doi:10.1007/978-981-95-3048-9_4
- Authors
- Mendoza-Ponce, P., John, B., Schroeder, D., & Krautschneider, W. H.
- Affiliations
- Hamburg University of Technology (DE)
- Venue
- 2018 14th Conference on Ph.D. Research in Microelectronics and Electronics (PRIME)
- Publisher
- IEEE
- Published
- 2018-07
- Pages
- 241-244
- OpenAlex
- W2887288801
- Cited by
- 19
- References
- 12
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 1 · 2021: 5 · 2020: 1 · 2019: 2
- FWCI
- 3.19
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference on Ph.D. Research in Microelectronics and Electronics (publishedVersion)
- tub.dok (Hamburg University of Technology) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Keywords
- supercapacitors, biomedical implants, wireless power transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›