The DOI matches its Crossref record.
Overview of IEC 61850 and Benefits
Abstract
Legacy substation automation protocols and architectures typically provided basic functionality for power system automation and were designed to accommodate the technical limitations of the networking technology available for implementation. There has recently been a vast improvement in networking technology that has changed dramatically what is now feasible for power system automation in the substation. Technologies such as switched Ethernet, TCP/IP, high-speed wide area networks, and high-performance low-cost computers are providing capabilities that could barely be imagined when most legacy substation automation protocols were designed. In order to take advantage of modern technology to deliver additional new benefits to users of substation automation, the International Electrotechnical Commission (IEC) has developed and released a new global standard for substation automation: IEC 61850. The paper will provide a basic technical overview of IEC 61850 and will discuss the benefits of each major aspect of the standard. The concept of a virtual model comprising both physical and logical device models that includes a set of standardized communications services will be described along with explanations of how these standardized models, object naming conventions, and communication services bring significant benefits to the substation automation user. New services to support self-describing devices and object-orient peer-to-peer data exchange will be explained with an emphasis on how these services can be applied to reduce costs for substation automation. The substation configuration language (SCL) of IEC 61850 will be presented with information on how the standardization of substation configuration will impact the future of substation automation. The paper will conclude with a brief introduction to the UCA International Users Group as a forum where users and suppliers cooperate in improving substation automation with testing, education, and demonstrations of IEC 61850 and other IEC standards technology
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
A Survey on Smart Grid Cyber-Physical System Testbeds
Cintuglu, M. H., Mohammed, O. A., Akkaya, K., & Uluagac, A. S. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2627399 · Cited by 421
León, H., Montez, C., Valle, O., & Vasques, F. (2019) · Energies · doi:10.3390/en12122272 · Cited by 35
Simulation of power system substation communications architecture based on IEC 61850 standard
Golshani, M., Taylor, G. A., & Pisica, I. (2014) · 2014 49th International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2014.6934745 · Cited by 21
Modeling Intelligent Control Switch IEC 61850 Based Substation Automation Communication
Nimma, K., & Faraj, S. (2018) · Applied System Innovation · doi:10.3390/asi1010007 · Cited by 14
Metadata
- Authors
- Mackiewicz, R. E.
- Venue
- 2006 IEEE PES Power Systems Conference and Exposition
- Publisher
- IEEE
- Published
- 2006
- Pages
- 623-630
- OpenAlex
- W2983647526
- Cited by
- 160
- References
- 0
- FWCI
- 2.12
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overview of IEC 61850 and Benefits. https://app.cochat.ai/papers/10.1109/psce.2006.296392
- The paper
- Mackiewicz, R. E. (2006). Overview of IEC 61850 and Benefits. 2006 IEEE PES Power Systems Conference and Exposition. https://doi.org/10.1109/psce.2006.296392
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.