Hosting capacity for photovoltaic inverters considering voltage unbalance
The DOI matches its Crossref record.
Abstract
In this paper the hosting capacity considering voltage unbalance is estimated for single-phase photovoltaic inverters (PVIs) in low-voltage distribution networks in Sweden. A stochastic approach is used to calculate the negative-sequence voltage unbalance for each of the possible locations in the network. The method has been applied to 6 and 28-customer networks for the connection of 6-kW single-phase PVIs. The impact of three-phase motors on the unbalance was also studied. From the results, it was observed that the contribution from single-phase photovoltaic inverters to the voltage unbalance likely exceeds 1%, but unlikely that it will reach 2% of voltage unbalance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State-of-the-art of hosting capacity in modern power systems with distributed generation
Ismael, S. M., Abdel Aleem, S. H. E., Abdelaziz, A. Y., & Zobaa, A. F. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.07.008 · Cited by 599
A Review of the Tools and Methods for Distribution Networks’ Hosting Capacity Calculation
Zain ul Abideen, M., Ellabban, O., & Al-Fagih, L. (2020) · Energies · doi:10.3390/en13112758 · Cited by 161
“[58] PV 4 Find the hosting capacity of LV rural distribution networks with regards to the negative-sequence voltage unbalance for single phase PV system integration.”
BackgroundUmoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Braga, M. D., Machado, S. D., Oliveira, I. C., de Oliveira, T. E. C., Ribeiro, P. F., & Lopes, B. I. L. (2018) · 2018 13th IEEE International Conference on Industry Applications (INDUSCON) · doi:10.1109/induscon.2018.8627342 · Cited by 23
Metadata
- Authors
- Schwanz, D., Ronnberg, S. K., & Bollen, M.
- Venue
- 2017 IEEE Manchester PowerTech
- Publisher
- IEEE
- Published
- 2017-06
- Volume
- 1
- Pages
- 1-6
- OpenAlex
- W2739035235
- Cited by
- 16
- References
- 0
- FWCI
- 2.33
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.