The DOI matches its Crossref record.
Grid-forming Inverter Experimental Testing of Fault Current Contributions
Open accessAbstract
Historically, photovoltaic inverters have been grid-following controlled, but with increasing penetrations of inverter-based generation on the grid, grid-forming inverters (GFMI) are gaining interest. GFMIs can also be used in microgrids that require the ability to interact and operate with the grid (grid-tied), or to operate autonomously (islanded) while supplying their corresponding loads. This approach can substantially improve the response of the grid to severe contingencies such as hurricanes, or to high load demands. During islanded conditions, GFMIs play an important role on dictating the system's voltage and frequency the same way as synchronous generators do in large interconnected systems. For this reason, it is important to understand the behavior of such grid-forming inverters under fault scenarios. This paper focuses on testing different commercially available grid-forming inverters under fault conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 10
- 10.1109/PVSC.2015.7356166 · DOI
- 10.1109/PVSC.2016.7749931 · DOI
- 10.1016/j.rser.2016.01.122 · DOI
- 10.1109/TPWRD.2010.2051819 · DOI
- 10.1109/MPE.2016.2637122 · DOI
- hernandez-alvidrez, 2019, Simulation of Grid-Forming Inverters Dynamic Models using a Power Hardware-in-the-Loop Testbed, IEEE Photovoltaic Specialists Conference (PVSC)
- wu, 2010, Voltage and frequency control of inverters connected in parallel forming a micro-grid, 2010 International Conference on Power System Technology
- 10.1109/PVSC.2018.8547449 · DOI
- 10.1109/PVSC.2018.8547488 · DOI
- 0, 1547-2018–IEEE Standard for Interconnecting and Interoperability Distributed Resources with Electric Power Systems Interfaces
Cited by
Sorted by citations
Small-Signal Analysis of Current-Limiting Grid-Forming Inverters
Yang, B., Baeckeland, N., & Seo, G.-S. (2026) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2026.3655646 · Cited by 2
Metadata
- Authors
- Gurule, N. S., Hernandez-Alvidrez, J., Reno, M. J., Summers, A., Gonzalez, S., & Flicker, J.
- Affiliations
- Sandia National Laboratories (US)
- Sandia National Laboratories,Albuquerque,New Mexico,USA,87123
- Venue
- 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC)
- Publisher
- IEEE
- Published
- 2019-06
- Pages
- 3150-3155
- ISSN
- 0160-8371 (ISSN-L)
- OpenAlex
- W3005256021
- Cited by
- 34
- References
- 0
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 5 · 2023: 6 · 2022: 7 · 2021: 5 · 2020: 5
- FWCI
- 6.57
- Type
- conference paper
- Language
- en
- Open access
- green
- www.osti.gov
- Locations
- Conference record of the IEEE Photovoltaic Specialists Conference (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- National Nuclear Security Administration (DENA-0003525)
- Sandia National Laboratories (DE‐NA,0003525)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- grid-forming inverters, fault current contribution, inverter-based resources, islanded operation, microgrids, grid-connected operation, fault ride-through, voltage and frequency regulation, photovoltaic inverter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review