The DOI matches its Crossref record; 214 of the 227 references it cites were found in a registry or an index.
Cochlear Implants: System Design, Integration, and Evaluation
Open accessAbstract
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–214 of 214
Chouard, C. H. (1980) · International Journal of Audiology · doi:10.3109/00206098009072656 · Cited by 20
Cochlear implants for adults and children
Clark, G. M. (2002) · CRC Press eBooks · doi:10.1201/b14730-30 · Cited by 17
Djourno, A., Eyriés, C., & Vallancien, P. (2000) · PubMed · Cited by 14
Recent Advances in Cochlear Implants
Zwolan, T. A. (2008) · Contemporary Issues in Communication Science and Disorders · doi:10.1044/cicsd_35_f_113 · Cited by 13
Edgerton, B. J., Doyle, K. J., Brimacombe, J. A., Danley, M. J., & Fretz, R. J. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31644.x · Cited by 13
Hearing Performance with the Auditory Prosthesis
Bilger, R. C., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s310 · Cited by 13
Measuring the Electrical Stapedius Reflex with Stapedius Muscle Electromyogram Recordings
Clement, R. S., Carter, P. M., & Kipke, D. R. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1454132 · Cited by 11
A Software Tool for Analyzing Multichannel Cochlear Implant Signals
Wai, K. L., Bögli, H., & Dillier, N. (2003) · Ear and Hearing · doi:10.1097/01.aud.0000090441.84986.8b · Cited by 11
Electrical Stimulation of the Auditory Nerve and Auditory Prostheses: A Review of the Literature
Bilger, R. C. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s302 · Cited by 8
Experiments with A Thinfilm Multichannel Electrode for Cochlear Implantation
Lauridsen, O., Günthersen, C., Bonding, P., & Tos, M. (1983) · Acta Oto-Laryngologica · doi:10.3109/00016488309130938 · Cited by 5
Subject acceptance of implanted auditory prosthesis.
Rc, B., Stenson, N., & Jl, P. (1977) · PubMed · Cited by 5
Role of temporal fine structure in speech perception
Zeng, F. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2935141 · Cited by 4
Self-citationUse of simultaneous stimulation to represent fine structure in cochlear implant processors
Litvak, L. M., Saoji, A. A., Spahr, A. J., Kulkarni, A., & Marzalek, M. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2932772 · Cited by 1
Acoustics 1989: Recent advances in cochlear implants
Shannon, R. V. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399558 · Cited by 1
Flagged first, then by citations
13 of the 227 references couldn’t be matched to a known paper.
Research works printed but not linked: 21
- luxford, 1985, Cochlear Implants, 92105, 1
- 10.1177/000348940711600401 · DOI
- 10.1097/MAO.0b013e318184f492 · DOI
- 1997, Multichannel Cochlear Implant System Including Wearable Speech Processor
- 2003, Multichannel Cochlear Implant with Neural Response Telemetry
- 2004, Transcutaneous Power Optimization Circuit for Cochlear Implant
- 2001, Power Transfer Circuit for Implanted Devices
- 1991, Transcutaneous Power and Signal Transmission System and Methods for Increased Signal Transmission Efficiency
- 1985, Cochlear Implant System for an Auditory Prosthesis
- robert, 2002, House Ear Institute Nucleus Research Interface (HEINRI) Users Guide
- 1998, Embedded Data Link and Protocol
- ricketts, 2002, Middle Ear Implants, 6
- 10.1097/01.mlg.0000167993.05007.35 · DOI
- 10.1080/00016480260000021 · DOI
- fraysse, 1998, Cochlear implants for adults obtaining marginal benefit from acoustic amplification, Am J Otol, 19, 591
- 10.1007/s101620020013 · DOI
- 10.1002/cii.45 · DOI
- 2006, Digitally Controlled RF Amplifier with Wide Dynamic Range Output
- 2001, High Compliance Output Stage for a Tissue Stimulator
- 2001, Programmable Current Output Stimulus Stage for Implantable Device
- 2006, Remote Control Unit for Use with an Implantable Neural Stimulator
Cited by
Sorted by citations
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 549
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model
Fotopoulou, K., & Flynn, B. W. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2093534 · Cited by 392
Wenger, N., Moraud, E. M., Gandar, J., Musienko, P., Capogrosso, M., Baud, L., Le Goff, C. G., Barraud, Q., Pavlova, N., Dominici, N., et al. (2016) · Nature Medicine · doi:10.1038/nm.4025 · Cited by 369
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
Metadata
- Authors
- Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H.
- Affiliations
- University of California, Irvine (US)
- University of California, San Francisco (US)
- Silere Med. Technol., Inc., Kirkland, WA
- Nurotron Biotechnol. Inc., Irvine, CA
- Chinese Academy of Sciences (CN)
- Corresponding author
- Zeng, Fan-Gang
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2008
- Volume
- 1
- Pages
- 115-142
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- PMC
- PMC2782849
- OpenAlex
- W2112854909
- Cited by
- 878
- References
- 227
- Citations by year
- 2026: 60 · 2025: 75 · 2024: 65 · 2023: 62 · 2022: 57 · 2021: 79 · 2020: 69 · 2019: 70 · 2018: 50 · 2017: 48 · 2016: 44 · 2015: 39 · 2014: 43 · 2013: 40 · 2012: 27
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (HHS-N-263-2007-00054-C, 5r01dc008858-05)
- U.S. Public Health Service (HHSN-263-2007-00054C)
- National Institute on Deafness and Other Communication Disorders (P30DC008369, HHSN263200700054C, R01-DC008858, R01DC002267)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
- Keywords
- cochlear implants, neural prostheses, hearing loss, system design, radio frequency transmission, stimulator, electrode arrays, system integration, safety and reliability, functional assessment, pediatric cochlear implant users, vestibular implant, retinal prosthesis
- MeSH terms
- Animals, Cochlear Implants, Humans, Prosthesis Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review