The DOI matches its Crossref record; 214 of the 227 references it cites were found in a registry or an index.
Cochlear Implants: System Design, Integration, and Evaluation
Open accessAbstract
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,302
Self-citationAcoustic Theory of Speech Production
Fant, G. (1971) · De Gruyter eBooks · doi:10.1515/9783110873429 · Cited by 2,966
Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
Sokal, N., & Sokal, A. D. (1975) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1975.1050582 · Cited by 2,036
Structure and function of auditory cortex: music and speech
Zatorre, R. J., Belin, P., & Penhune, V. B. (2002) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(00)01816-7 · Cited by 1,582
van de Ven, & Haines, A. (1999) · Medical Entomology and Zoology · Cited by 1,421
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,211
Temporal information in speech: acoustic, auditory and linguistic aspects
Rosen, S. (1992) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1992.0070 · Cited by 1,142
Factors Governing the Intelligibility of Speech Sounds
French, N. R., & Steinberg, J. C. (1947) · The Journal of the Acoustical Society of America · doi:10.1121/1.1916407 · Cited by 1,137
Bryson, J. (2017) · Routledge eBooks · doi:10.4324/9781315256894-38 · Cited by 1,135
Rf, G. (1985) · Cited by 949
Chimaeric sounds reveal dichotomies in auditory perception
Smith, Z. M., Delgutte, B., & Oxenham, A. J. (2002) · Nature · doi:10.1038/416087a · Cited by 879
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
A Socio-Cognitive Model of Technology Evolution: The Case of Cochlear Implants
Garud, R. B., & Rappa, M. A. (1994) · Organization Science · doi:10.1287/orsc.5.3.344 · Cited by 652
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 618
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 509
Speech and Hearing in Communication.
Fletcher, H. (1953) · JAMA · doi:10.1001/jama.1953.03690130101041 · Cited by 508
Gantz, B. J., Turner, C. W., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 466
Frequency Map for the Human Cochlear Spiral Ganglion: Implications for Cochlear Implants
Stakhovskaya, O. A., Sridhar, D., Bonham, B. H., & Leake, P. A. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0076-9 · Cited by 415
Zeng, F. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 404
Self-citationEthylene oxide sterilization of medical devices: A review
Mendes, G. C., Brandão, T. R. S., & Silva, C. L. M. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2006.10.014 · Cited by 398
Nadol, J. B., Young, Y.-S., & Glynn, R. J. (1989) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948909800602 · Cited by 396
Auditory‐Nerve Activity in Cats with Normal and Abnormal Cochleas
Kiang, N. Y. S., Moxon, E. C., & Levine, R. A. (1970) · Novartis Foundation symposium · doi:10.1002/9780470719756.ch15 · Cited by 386
Speech recognition with amplitude and frequency modulations
Zeng, F., Nie, K., Stickney, G. S., Kong, Y.-Y., Vongphoe, M., Bhargave, A., Wei, C., & Cao, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406460102 · Cited by 383
Self-citationFishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech Language and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 382
The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes
Escudé, B., James, C. J., Déguine, O., Cochard, N., Eter, E., & Fraysse, B. (2006) · Audiology and Neurotology · doi:10.1159/000095611 · Cited by 380
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 378
Self-citationExact analysis of class E tuned power amplifier at any Q and switch duty cycle
Kazimierczuk, M. K., & Puczko, K. (1987) · IEEE Transactions on Circuits and Systems · doi:10.1109/tcs.1987.1086114 · Cited by 372
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Risk of Bacterial Meningitis in Children with Cochlear Implants
Reefhuis, J., Honein, M. A., Whitney, C. G., Chamany, S., MANN, E. A., Biernath, K. R., Broder, K. R., Manning, S. E., Avashia, S. B., Victor, M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031101 · Cited by 360
Long Term Results of Electrode Implantation and Electronic Stimulation of the Cochlea in Man
House, W. F., & Urban, J. (1973) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348947308200408 · Cited by 354
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 352
Self-citationFlanagan, J. L., & Golden, R. M. (1966) · Bell System Technical Journal · Cited by 348
Volta, A. (1800) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1800.0018 · Cited by 342
Cochlear implant speech recognition with speech maskers
Stickney, G. S., Zeng, F., Litovsky, R. Y., & Assmann, P. F. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1772399 · Cited by 340
Self-citationAuditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Abbas, P. J., Brown, C., Shallop, J. K., Firszt, J. B., Hughes, M. L., Hong, S. H., & Staller, S. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00005 · Cited by 324
Temporal pitch in electric hearing
Zeng, F. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 323
Self-citationFeedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults
Aschendorff, A., Kromeier, J., Klenzner, T., & Laszig, R. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e318031542e · Cited by 311
Vandali, A. E., Whitford, L. A., Plant, K. L., & Clark, A. G. M. (2000) · Ear and Hearing · doi:10.1097/00003446-200012000-00008 · Cited by 309
Speech waveform envelope cues for consonant recognition
Tasell, D. J. V., Soli, S. D., Kirby, V. M., & Widin, G. P. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395251 · Cited by 293
Histopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J.-Y., Eddington, D. K., Montandon, P. B., et al. (2001) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Cost-Utility Analysis of the Cochlear Implant in Children
Cheng, A. K. (2000) · JAMA · doi:10.1001/jama.284.7.850 · Cited by 281
Rubinstein, J. T., Wilson, B. S., Finley, C. C., & Abbas, P. J. (1999) · Hearing Research · doi:10.1016/s0378-5955(98)00185-3 · Cited by 276
Dorman, M. F., Gifford, R. H., Spahr, A. J., & McKarns, S. A. (2007) · Audiology and Neurotology · doi:10.1159/000111782 · Cited by 275
Schleich, P., Nopp, P., & D'Haese, P. S. C. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000130792.43315.97 · Cited by 269
Speech and Hearing in Communication
Barbour, J. M., & Fletcher, H. (1953) · Notes · doi:10.2307/893762 · Cited by 263
In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
Skinner, M. W., Holden, T. A., Whiting, B. R., Voie, A. H., Brunsden, B. S., Neely, J. G., Saxon, E. A., Hullar, T. E., & Finley, C. C. (2007) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940711600401 · Cited by 243
Temporal processing and speech recognition in cochlear implant users
Fu, Q. (2002) · Neuroreport · doi:10.1097/00001756-200209160-00013 · Cited by 238
Fraysse, B., Macías, Á. R., Sterkers, O., Burdo, S., Ramsden, R. T., Déguine, O., Klenzner, T., Lenarz, T., Manrique, M. J., von Wallenberg, E., et al. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000226289.04048.0f · Cited by 236
Adunka, O. F., Unkelbach, M. H., Mack, M. G., Hambek, M., Gstoettner, W. K., & Kiefer, J. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410018179 · Cited by 229
Skinner, M. W., Ketten, D. R., Holden, L. K., Harding, G. W., Smith, P. G., Gates, G. A., Neely, J. G., Kletzker, G. R., Brunsden, B. S., & Blocker, B. (2002) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620020013 · Cited by 224
McDermott, H. J., McKay, C. M., & Vandali, A. E. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402826 · Cited by 219
The Development of the Nucleus® Freedom™ Cochlear Implant System
Patrick, J., Busby, P., & Gibson, P. (2006) · Trends in Amplification · doi:10.1177/1084713806296386 · Cited by 214
Temporal modulation transfer functions in patients with cochlear implants
Shannon, R. V. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.403807 · Cited by 213
Encoding Frequency Modulation to Improve Cochlear Implant Performance in Noise
Nie, K., Stickney, G. S., & Zeng, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839799 · Cited by 211
Self-citationHow cochlear implants encode speech
Rubinstein, J. T. (2004) · Current Opinion in Otolaryngology & Head & Neck Surgery · doi:10.1097/01.moo.0000134452.24819.c0 · Cited by 208
Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant
Gantz, B. J., & Turner, C. W. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016423 · Cited by 204
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Current focusing and steering: Modeling, physiology, and psychophysics
Bonham, B. H., & Litvak, L. M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.03.006 · Cited by 198
Dorman, M. F., Loizou, P. C., Fitzke, J., & Tu, Z. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423940 · Cited by 197
A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation
Hashimoto, T., Elder, C. M., & Vitek, J. L. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00491-5 · Cited by 195
Impact of electrode insertion depth on intracochlear trauma
Adunka, O. F., & Kiefer, J. (2006) · Otolaryngology · doi:10.1016/j.otohns.2006.05.002 · Cited by 194
Roland, J. T. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000167993.05007.35 · Cited by 194
Thermal effects of bioimplants
Lazzi, G. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511503 · Cited by 193
Auditory Nerve: Electrical Stimulation in Man
Simmons, F. B., Epley, J. M., Lummis, R. C., Guttman, N., Frishkopf, L. S., Harmon, L. D., & Zwicker, E. (1965) · Science · doi:10.1126/science.148.3666.104 · Cited by 191
Luo, X., Fu, Q., & Galvin, J. J. (2007) · Trends in Amplification · doi:10.1177/1084713807305301 · Cited by 191
Cochlear Compression: Perceptual Measures and Implications for Normal and Impaired Hearing
Oxenham, A. J., & Bacon, S. P. (2003) · Ear and Hearing · doi:10.1097/01.aud.0000090470.73934.78 · Cited by 190
MED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I. J., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 187
Speech discrimination in deaf subjects with cochlear implants
Eddington, D. K. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384827 · Cited by 186
Auditory Cortical Images of Cochlear-Implant Stimuli: Dependence on Electrode Configuration
Bierer, J. A., & Middlebrooks, J. C. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00212.2001 · Cited by 177
Santina, C. C. D., Migliaccio, A. A., & Patel, A. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894629 · Cited by 173
Micropower Circuits for Bidirectional Wireless Telemetry in Neural Recording Applications
Neihart, N., & Harrison, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856247 · Cited by 172
Speech dynamic range and its effect on cochlear implant performance
Zeng, F., Grant, G., Niparko, J. K., Galvin, J. J., Shannon, R. V., Opie, J. M., & Segel, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1423926 · Cited by 171
Self-citationGantz, B. J., Turner, C. W., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
Three Mechanisms of Hearing by Electrical Stimulation
Jones, R. C., Stevens, S. S., & Lurie, M. H. (1940) · The Journal of the Acoustical Society of America · doi:10.1121/1.1916103 · Cited by 169
Rebscher, S. J. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.08.0119 · Cited by 169
Self-citationGfeller, K. E., Witt, S., Mehr, M. A., Woodworth, G. G., & Knutson, J. F. (2002) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940211100412 · Cited by 164
Smoorenburg, G. F., Willeboer, C., & van Dijk, J. E. (2002) · Audiology and Neurotology · doi:10.1159/000066154 · Cited by 163
Maximizing cochlear implant patients’ performance with advanced speech training procedures
Fu, Q., & Galvin, J. J. (2007) · Hearing Research · doi:10.1016/j.heares.2007.11.010 · Cited by 162
Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners
Zeng, F., & Galvin, J. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00006 · Cited by 162
Self-citationAuditory Prosthesis with a Penetrating Nerve Array
Middlebrooks, J. C., & Snyder, R. L. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0070-2 · Cited by 159
The Nucleus 22-Channel Cochlear Implant System
Patrick, J. F., & Clark, G. M. (1991) · Ear and Hearing · doi:10.1097/00003446-199108001-00002 · Cited by 156
Quality Control after Cochlear Implant Surgery by Means of Rotational Tomography
Aschendorff, A., Kubalek, R., Turowski, B., Zanella, F. E., Hochmuth, A., Schumacher, M. C., Klenzner, T., & Laszig, R. (2005) · Otology & Neurotology · doi:10.1097/00129492-200501000-00007 · Cited by 155
Frijns, J. H. M., Briaire, J. J., & Grote, J. J. (2001) · Otology & Neurotology · doi:10.1097/00129492-200105000-00012 · Cited by 155
Temporal Bone Results and Hearing Preservation with a New Straight Electrode
Lenarz, T., Stöver, T., Buechner, A., Paasche, G., Briggs, R., Risi, F., Pesch, J., & Battmer, R. (2006) · Audiology and Neurotology · doi:10.1159/000095612 · Cited by 154
Characterization of the electrically evoked auditory brainstem response (ABR) in cats and humans
van den Honert, C., & Stypulkowski, P. H. (1986) · Hearing Research · doi:10.1016/0378-5955(86)90033-x · Cited by 150
Current steering creates additional pitch percepts in adult cochlear implant recipients
Firszt, J. B., Koch, D. B., Downing, M., & Litvak, L. (2007) · Otology & Neurotology · doi:10.1097/01.mao.0000281803.36574.bc · Cited by 150
Briggs, R., Tykocinski, M., Xu, J. Y., Risi, F., Svehla, M., Cowan, R., Stöver, T., Erfurt, P., & Lenarz, T. (2006) · Audiology and Neurotology · doi:10.1159/000095613 · Cited by 149
Schwartz, M. S., Otto, S. R., Shannon, R. V., Hitselberger, W. E., & Brackmann, D. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.068 · Cited by 149
Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea
Frijns, J. H. M., de Snoo, S. L., & ten Kate, J. H. (1996) · Hearing Research · doi:10.1016/0378-5955(96)00004-4 · Cited by 146
Bacterial Meningitis Among Children With Cochlear Implants Beyond 24 Months After Implantation
Biernath, K. R., Reefhuis, J., Whitney, C. G., MANN, E. A., Costa, P., Eichwald, J., & Boyle, C. A. (2006) · PEDIATRICS · doi:10.1542/peds.2005-0824 · Cited by 144
Spectral and Temporal Cues in Cochlear Implant Speech Perception
Nie, K., Barco, A., & Zeng, F. (2006) · Ear and Hearing · doi:10.1097/01.aud.0000202312.31837.25 · Cited by 144
Self-citationResearch Plan for Evaluating Subjects Presently Fitted with Implanted Auditory Prostheses
Bilger, R. C., Black, F. O., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s303 · Cited by 142
Electrical Stimulation of Eighth Cranial Nerve
Doyle, J. H., DOYLE, J. B., & Turnbull, F. M. (1964) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1964.00750040400005 · Cited by 138
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
Wardrop, P. J. C., Whinney, D., Rebscher, S. J., Roland, J. T., Luxford, W. M., & Leake, P. A. (2004) · Hearing Research · doi:10.1016/j.heares.2004.11.006 · Cited by 135
Self-citationHarnack, D., Winter, C., Meissner, W. G., Reum, T., Kupsch, A. R., & Morgenstern, R. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.04.019 · Cited by 131
Enhancing temporal cues to voice pitch in continuous interleaved sampling cochlear implants
Green, T. J., Faulkner, A., & Rosen, S. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1785611 · Cited by 130
Skinner, M. W., Holden, L. K., Holden, T. A., Dowell, R. C., Seligman, P., Brimacombe, J. A., & Beiter, A. L. (1991) · Ear and Hearing · doi:10.1097/00003446-199102000-00002 · Cited by 130
The Results of Electrical Stimulation of the Cochlea in Human Sensory Deafness
Michelson, R. P. (1971) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348947108000618 · Cited by 128
The Mechanism of Hearing by Electrical Stimulation
Stevens, S. S., & Jones, R. C. (1939) · The Journal of the Acoustical Society of America · doi:10.1121/1.1915984 · Cited by 127
Speech and music perception with the new fine structure speech coding strategy: preliminary results
Arnoldner, C., Riss, D., Brunner, M., Ďurišin, M., Baumgartner, W., & Hamzavi, J. (2007) · Acta Oto-Laryngologica · doi:10.1080/00016480701275261 · Cited by 125
The University of Melbourne--nucleus multi-electrode cochlear implant.
Clark, G. M., Blamey, P. J., Brown, A. M., Gusby, P. A., Dowell, R. C., Franz, B. K.-H. G., Pyman, B. C., Shepherd, R. K., Tong, Y. C., & Webb, R. L. (1987) · PubMed · Cited by 124
Improved Music Perception with Explicit Pitch Coding in Cochlear Implants
Laneau, J., Wouters, J. M., & Moonen, M. (2005) · Audiology and Neurotology · doi:10.1159/000088853 · Cited by 124
An Improved Method of Reducing Stimulus Artifact in the Electrically Evoked Whole-Nerve Potential
Miller, C. A., Abbas, P. J., & Brown, C. (2000) · Ear and Hearing · doi:10.1097/00003446-200008000-00003 · Cited by 122
A novel stimulus artifact removal technique for high-rate electrical stimulation
Heffer, L. F., & Fallon, J. B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.01.023 · Cited by 121
Acoustic to Electric Pitch Comparisons in Cochlear Implant Subjects with Residual Hearing
Boëx, C., Baud, L., Cosendai, G., Sigrist, A., Kós, M.-I., & Pelizzone, M. (2006) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-005-0027-2 · Cited by 120
Mandarin tone recognition in cochlear-implant subjects
Wei, C., Cao, K., & Zeng, F. (2004) · Hearing Research · doi:10.1016/j.heares.2004.06.002 · Cited by 118
Self-citationEffect of Different Types of Electrodes in Electrophonic Hearing
Flottorp, G. (1953) · The Journal of the Acoustical Society of America · doi:10.1121/1.1907027 · Cited by 117
Loudness-Coding Mechanisms Inferred from Electric Stimulation of the Human Auditory System
Zeng, F., & Shannon, R. V. (1994) · Science · doi:10.1126/science.8160013 · Cited by 116
Self-citationSignal-processing techniques for cochlear implants
Laizou, P. C. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765187 · Cited by 116
The Contour Electrode Array: Safety Study and Initial Patient Trials of a New Perimodiolar Design
Tykocinski, M., Saunders, E., Cohen, L. T., Treaba, C. G., Briggs, R., Gibson, P., Clark, G. M., & Cowan, R. (2001) · Otology & Neurotology · doi:10.1097/00129492-200101000-00007 · Cited by 114
Electrical stimulation of the auditory nerve: direct current measurement in vivo
Huang, C., Shepherd, R. K., P.M. Center, Seligman, P., & Tabor, B. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.752943 · Cited by 114
Performance of Patients Using Different Cochlear Implant Systems: Effects of Input Dynamic Range
Spahr, A. J., Dorman, M. F., & Loiselle, L. H. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e3180312607 · Cited by 113
Djourno, A., & Eyriés, C. (1957) · PubMed · Cited by 112
Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays
Tykocinski, M., Cohen, L. T., Pyman, B. C., ROLANDJR, T., Treaba, C. G., Palamara, J. E. A., DAHM, M., Shepherd, R. K., Xu, J., & Cowan, R. S. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80010-1 · Cited by 112
A Cost-Utility Scenario Analysis of Bilateral Cochlear Implantation
Summerfield, A. Q., Marshall, D. H., Barton, G., & Bloor, K. E. (2002) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.128.11.1255 · Cited by 111
Using Current Steering to Increase Spectral Resolution in CII and HiRes 90K Users
Koch, D. B., Downing, M., Osberger, M. J., & Litvak, L. M. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e31803150de · Cited by 105
Nucleus Freedom North American Clinical Trial
Bałkany, T. J., Hodges, A. V., Menapace, C., Hazard, L., Driscoll, C. L. W., Gantz, B. J., Kelsall, D. C., Luxford, W. M., McMenomy, S., Neely, J. G., et al. (2007) · Otolaryngology · doi:10.1016/j.otohns.2007.01.006 · Cited by 105
Cochlear Implant Deep Electrode Insertion: Extent of Insertional Trauma
Gstoettner, W. K., Plenk, H., Jr., Franz, P., Hamzavi, J. S., Baumgartner, W., Czerny, C., & Ehrenberger, K. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709117786 · Cited by 105
Lenarz, T., Lim, H. H., Reuter, G., Patrick, J. F., & Lenarz, M. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000232010.01116.e9 · Cited by 104
Initial Clinical Experience With a Totally Implantable Cochlear Implant Research Device
Briggs, R., Eder, H. C., Seligman, P., Cowan, R., Plant, K. L., Dalton, J. C. H., Money, D. K., & Patrick, J. F. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e31814b242f · Cited by 103
Wardrop, P. J. C., Whinney, D., Rebscher, S. J., Luxford, W. M., & Leake, P. A. (2004) · Hearing Research · doi:10.1016/j.heares.2004.11.007 · Cited by 99
Self-citationForward-masked spatial tuning curves in cochlear implant users
Nelson, D. A., Donaldson, G. S., & Kreft, H. A. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2836786 · Cited by 97
Chronic Vestibulo-Ocular Reflexes Evoked by a Vestibular Prosthesis
Merfeld, D. M., Haburcakova, C., Gong, W., & Lewis, R. F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891943 · Cited by 97
Unintelligible Low-Frequency Sound Enhances Simulated Cochlear-Implant Speech Recognition in Noise
Chang, J. E., Bai, J. Y., & Zeng, F. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883793 · Cited by 95
Self-citationKoch, D. B., Osberger, M. J., Segel, P., & Kessler, D. K. (2004) · Audiology and Neurotology · doi:10.1159/000078391 · Cited by 93
Effects of Stimulation Rate on Speech Recognition with Cochlear Implants
Friesen, L. M., Shannon, R. V., & Cruz, R. J. (2005) · Audiology and Neurotology · doi:10.1159/000084027 · Cited by 92
Green, T., Faulkner, A., Rosen, S., & Macherey, O. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1925827 · Cited by 92
Dorman, M. F., Spahr, T., Gifford, R. H., Loiselle, L. H., McKarns, S. A., Holden, T. A., Skinner, M. W., & Finley, C. C. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0071-1 · Cited by 91
Cochlear nucleus auditory prostheses
McCreery, D. B. (2008) · Hearing Research · doi:10.1016/j.heares.2007.11.014 · Cited by 89
Flanagan, J. L., Meinhart, D. I. S., Golden, R. M., & Sondhi, M. M. (1965) · The Journal of the Acoustical Society of America · doi:10.1121/1.1939800 · Cited by 87
Combined Electroacoustic Stimulation in Conventional Candidates for Cochlear Implantation
James, C. J., Fraysse, B., Déguine, O., Lenarz, T., Mawman, D. J., Ramos, Á., Ramsden, R. T., & Sterkers, O. (2006) · Audiology and Neurotology · doi:10.1159/000095615 · Cited by 86
Loudness balance between electric and acoustic stimulation
Zeng, F., & Shannon, R. V. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90024-h · Cited by 85
Self-citationCochlear implant electrode configuration effects on activation threshold and tonotopic selectivity
Snyder, R. L., Middlebrooks, J. C., & Bonham, B. H. (2007) · Hearing Research · doi:10.1016/j.heares.2007.09.013 · Cited by 85
Briggs, R., Tykocinski, M., Saunders, E., Hellier, W. P. L., Dahm, M. C., Pyman, B. C., & Clark, G. M. (2001) · Cochlear Implants International · doi:10.1179/cim.2001.2.2.135 · Cited by 83
Potts, L. G., Skinner, M. W., Gotter, B. D., Strube, M., & Brenner, C. A. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e31806dc16e · Cited by 82
Speaker recognition with temporal cues in acoustic and electric hearing
Vongphoe, M., & Zeng, F. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1944507 · Cited by 82
Self-citationLaneau, J., Wouters, J. M., & Moonen, M. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1823311 · Cited by 81
An advanced multiple channel cochlear implant
McDermott, H. J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32112 · Cited by 81
Two New Directions in Speech Processor Design for Cochlear Implants
Wilson, B. S., Schatzer, R., Lopez‐Poveda, E. A., Sun, X., Lawson, D. T., & Wolford, R. D. (2005) · Ear and Hearing · doi:10.1097/00003446-200508001-00009 · Cited by 79
Self-citationA computer interface for psychophysical and speech research with the Nucleus cochlear implant
Shannon, R. V., Adams, D. D., Ferrel, R. L., Palumbo, R. L., & Grandgenett, M. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.398902 · Cited by 78
Meningitis in Cochlear Implant Recipients: The North American Experience
Cohen, N. L., Roland, J. T., & Marrinan, M. S. (2004) · Otology & Neurotology · doi:10.1097/00129492-200405000-00013 · Cited by 76
Laback, B., & Majdak, P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709199105 · Cited by 76
Design for a Simplified Cochlear Implant System
An, S. K., Park, S.-I., Jun, S. B., Lee, C. J., Byun, K. M., Sung, J. H., Wilson, B. S., Rebscher, S. J., Oh, S. H., & Kim, S. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895372 · Cited by 76
Self-citationThe Nucleus Contour Electrode Array: A Radiological and Histological Study
Richter, B., Aschendorff, A., Lohnstein, P., Husstedt, H. W., Nagursky, H., & Laszig, R. (2001) · The Laryngoscope · doi:10.1097/00005537-200103000-00023 · Cited by 75
Comparative studies of speech processing strategies for cochlear implants
Wilson, B. S., Finley, C. C., Weber, B. A., White, M. W., Farmer, J. C., Wolford, R. D., Merzenich, M. M., Lawson, D. T., Kenan, P. D., & Schindler, R. A. (1988) · The Laryngoscope · doi:10.1288/00005537-198810000-00009 · Cited by 74
Auditory Outcomes in Tumor vs. Nontumor Patients Fitted with Auditory Brainstem Implants
Colletti, V. (2006) · Advances in oto-rhino-laryngology · doi:10.1159/000094651 · Cited by 72
A Novel Speech-Processing Strategy Incorporating Tonal Information for Cochlear Implants
Lan, N., Nie, K., Gao, S., & Zeng, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826597 · Cited by 72
Self-citationThe Surprising Performance of Present-Day Cochlear Implants
Wilson, B. S., & Dorman, M. F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893505 · Cited by 72
Lim, H. H., Lenarz, T., Joseph, G., Battmer, R., Samii, A., Samii, M., Patrick, J. F., & Lenarz, M. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.3123-07.2007 · Cited by 71
ver, T. S., Issing, P. R., Graurock, G., Erfurt, P., Elbeltagy, Y. M., Paasche, G., & Lenarz, T. (2005) · Otology & Neurotology · doi:10.1097/01.mao.0000179527.17285.85 · Cited by 70
Tone production of Mandarin Chinese speaking children with cochlear implants
Han, D., Zhou, N., Li, Y., Chen, X., Zhao, X., & Xu, L. (2007) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2007.02.008 · Cited by 70
Speech Perception Using Maps Based on Neural Response Telemetry Measures
Seyle, K., & Brown, C. (2002) · Ear and Hearing · doi:10.1097/00003446-200202001-00009 · Cited by 69
Binaural Unmasking with Bilateral Cochlear Implants
Long, C. J., Carlyon, R. P., Litovsky, R. Y., & Downs, D. H. (2006) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-006-0049-4 · Cited by 68
Blamey, P. J., Dowell, R. C., Clark, G. M., & Seligman, P. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395542 · Cited by 64
Strategies to improve electrode positioning and safety in cochlear implants
Rebscher, S. J., Heilmann, M. R., Bruszewski, W., Talbot, N. H., Snyder, R. L., & Merzenich, M. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748987 · Cited by 62
Self-citationChen, B. K., Clark, G. M., & Jones, R. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00150-9 · Cited by 60
Four years of experience with cochlear prostheses.
Hochmair-Desoyer, I. J., Hochmair, E. S., Burian, K., & FISCHER, R. E. (1981) · PubMed · Cited by 60
Fraysse, B., Dillier, N., Klenzner, T., Laszig, R., Manrique, M. J., Pérez, C. M., Morgon, A., Müller-Deile, J., & Macías, Á. R. (1998) · PubMed · doi:10.5167/uzh-8346 · Cited by 58
Rebscher, S. J., Snyder, R. L., & Leake, P. A. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1365115 · Cited by 55
Self-citationModiolar Proximity of Three Perimodiolar Cochlear Implant Electrodes
Bałkany, T. J., Eshraghi, A. A., & Yang, N. W. (2002) · Acta Oto-Laryngologica · doi:10.1080/00016480260000021 · Cited by 54
An empirically based model of the electrically evoked compound action potential
Miller, C. A., Abbas, P. J., & Rubinstein, J. T. (1999) · Hearing Research · doi:10.1016/s0378-5955(99)00081-7 · Cited by 49
Stiffness properties for Nucleus standard straight and contour electrode arrays
Kha, H., Chen, B. K., Clark, G. M., & Jones, R. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.05.001 · Cited by 48
Adunka, O. F., Pillsbury, H. C., & Kiefer, J. (2006) · Acta Oto-Laryngologica · doi:10.1080/00016480500437393 · Cited by 46
On Hearing by Electrical Stimulation
Stevens, S. S. (1937) · The Journal of the Acoustical Society of America · doi:10.1121/1.1902000 · Cited by 45
Acoustic cues for consonant identification by patients who use the Ineraid cochlear implant
Dorman, M. F., Soli, S. D., Dankowski, K., Smith, L. M., McCandless, G. A., & Parkin, J. L. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.400104 · Cited by 45
Programming the cochlear implant based on electrical acoustic reflex thresholds: Patient performance
Spivak, L. G., Chute, P. M., Popp, A. L., & Parisier, S. C. (1994) · The Laryngoscope · doi:10.1288/00005537-199410000-00007 · Cited by 44
James, C. J., Skinner, M. W., Martin, L. F. A., Holden, L. K., Galvin, K. L., Holden, T. A., & Whitford, L. A. (2003) · Ear and Hearing · doi:10.1097/01.aud.0000058107.64929.d6 · Cited by 43
Clinical Evaluation of the Clarion CII HiFocus 1 with and Without Positioner
van der Beek, F. B., Boermans, P. P. B. M., Verbist, B. M., Briaire, J. J., & Frijns, J. H. M. (2005) · Ear and Hearing · doi:10.1097/01.aud.0000188116.30954.21 · Cited by 43
On Hearing by Electrical Stimulation
Stevens, S. S. (1937) · The Journal of the Acoustical Society of America · doi:10.1121/1.1915894 · Cited by 41
Coding strategies for multichannel cochlear prostheses.
Wilson, B. S., Lawson, D. T., Finley, C. C., & Wolford, R. D. (1991) · PubMed · Cited by 38
Development of a Novel Eighth‐Nerve Intraneural Auditory Neuroprosthesis
Badi, A. N., Kertesz, T. R., Gurgel, R. K., Shelton, C., & Normann, R. A. (2003) · The Laryngoscope · doi:10.1097/00005537-200305000-00012 · Cited by 38
Clinical Evaluation of Higher Stimulation Rates in the Nucleus Research Platform 8 System
Plant, K. L., Holden, L. K., Skinner, M., Arcaroli, J., Whitford, L. A., Law, M.-A., & Nel, E. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e31804793ac · Cited by 38
Plant, K. L., Law, M.-A., Whitford, L. A., Knight, M. R., Tari, S., Leigh, J., Pedley, K., & Nel, E. (2005) · Ear and Hearing · doi:10.1097/01.aud.0000188201.86799.01 · Cited by 37
Busby, P. A., & Plant, K. L. (2005) · Ear and Hearing · doi:10.1097/01.aud.0000179693.32989.84 · Cited by 33
Richter, B., Aschendorff, A., Lohnstein, P., Husstedt, H. W., Nagursky, H., & Laszig, R. (2002) · The Journal of Laryngology & Otology · doi:10.1258/002221502760132584 · Cited by 32
Evaluation of the Short Hybrid Electrode in Human Temporal Bones
Roland, J. T., Zeitler, D. M., Jethanamest, D., & Huang, T. C. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e31816845eb · Cited by 29
A transparent model of the human scala tympani cavity
Rebscher, S. J., Talbot, N., Bruszewski, W., Heilmann, M. R., Brasell, J., & Merzenich, M. M. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00116-6 · Cited by 28
Self-citationThirty Years of Vocoder Research
Dudley, H. (1964) · The Journal of the Acoustical Society of America · doi:10.1121/1.2143221 · Cited by 27
Fu, Q., & Shannon, R. V. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.427031 · Cited by 27
Wakefield, G. H., van den Honert, C., Parkinson, W. S., & Lineaweaver, S. (2005) · Ear and Hearing · doi:10.1097/00003446-200508001-00008 · Cited by 27
A Signal Processor for a Multiple-electrode Hearing Prosthesis
Seligman, P., Patrick, J. F., Tong, Y. C., Clark, G. M., Dowell, R. C., & Crosby, P. A. (1984) · Acta Oto-Laryngologica · doi:10.3109/00016488409099557 · Cited by 27
Auditory Prostheses in Perspective
Bilger, R. C., & Black, F. O. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s301 · Cited by 27
Anatomical Considerations and Long-Term Effects of Electrical Stimulation
Leake, P. A., & Rebscher, S. J. (2004) · Springer handbook of auditory research · doi:10.1007/978-0-387-22585-2_4 · Cited by 26
Self-citationHuang, C. Q., Shepherd, R. K., Seligman, P., & Clark, G. M. (1998) · Hearing Research · doi:10.1016/s0378-5955(97)00196-2 · Cited by 26
Morton, K. D., Kucukoglu, M. S., Remus, J. J., & Collins, L. M. (2006) · Hearing Research · doi:10.1016/j.heares.2006.03.020 · Cited by 25
Advanced Bionics Thin Lateral and Helix II Electrodes: A Temporal Bone Study
Wright, C. G., Roland, P. S., & Kuzma, J. A. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000181461.63392.49 · Cited by 25
Are Cochlear Implant Patients Suffering From Perceptual Dissonance?
Loeb, G. E. (2005) · Ear and Hearing · doi:10.1097/01.aud.0000179688.87621.48 · Cited by 25
Cochlear Implants and Meningitis in Children
Whitney, C. G. (2004) · The Pediatric Infectious Disease Journal · doi:10.1097/01.inf.0000136818.94301.db · Cited by 24
Psychoacoustic evaluation of present prostheses.
Rc, B. (1977) · PubMed · Cited by 24
Compression and Cochlear Implants
Fg, Z. (2006) · Springer eBooks · doi:10.1007/0-387-21530-1_6 · Cited by 22
Effects of Inner Ear Trauma on the Risk of Pneumococcal Meningitis
Wei, B. P. C., Shepherd, R. K., Robins-Browne, R. M., Clark, G. M., & O’Leary, S. J. (2007) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.133.3.250 · Cited by 22
Hearing with bionic ears [cochlear implant devices]
Ay, S. U., Zeng, F., & Sheu, B. J. (1997) · IEEE Circuits and Devices Magazine · doi:10.1109/101.589259 · Cited by 21
Self-citationDjourno, A., Eyriés, C., & Vallancien, B. (1957) · PubMed · Cited by 21
THIN‐FILM ELECTRODE FABRICATION TECHNIQUESa
White, R. L., Roberts, L. A., Cotter, N. E., & Kwon, O. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31631.x · Cited by 20
Research works printed but not linked: 21
- luxford, 1985, Cochlear Implants, 92105, 1
- 10.1177/000348940711600401 · DOI
- 10.1097/MAO.0b013e318184f492 · DOI
- 1997, Multichannel Cochlear Implant System Including Wearable Speech Processor
- 2003, Multichannel Cochlear Implant with Neural Response Telemetry
- 2004, Transcutaneous Power Optimization Circuit for Cochlear Implant
- 2001, Power Transfer Circuit for Implanted Devices
- 1991, Transcutaneous Power and Signal Transmission System and Methods for Increased Signal Transmission Efficiency
- 1985, Cochlear Implant System for an Auditory Prosthesis
- robert, 2002, House Ear Institute Nucleus Research Interface (HEINRI) Users Guide
- 1998, Embedded Data Link and Protocol
- ricketts, 2002, Middle Ear Implants, 6
- 10.1097/01.mlg.0000167993.05007.35 · DOI
- 10.1080/00016480260000021 · DOI
- fraysse, 1998, Cochlear implants for adults obtaining marginal benefit from acoustic amplification, Am J Otol, 19, 591
- 10.1007/s101620020013 · DOI
- 10.1002/cii.45 · DOI
- 2006, Digitally Controlled RF Amplifier with Wide Dynamic Range Output
- 2001, High Compliance Output Stage for a Tissue Stimulator
- 2001, Programmable Current Output Stimulus Stage for Implantable Device
- 2006, Remote Control Unit for Use with an Implantable Neural Stimulator
Cited by
Sorted by citations
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 549
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model
Fotopoulou, K., & Flynn, B. W. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2093534 · Cited by 392
Wenger, N., Moraud, E. M., Gandar, J., Musienko, P., Capogrosso, M., Baud, L., Le Goff, C. G., Barraud, Q., Pavlova, N., Dominici, N., et al. (2016) · Nature Medicine · doi:10.1038/nm.4025 · Cited by 369
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
Metadata
- Authors
- Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H.
- Affiliations
- University of California, Irvine (US)
- University of California, San Francisco (US)
- Silere Med. Technol., Inc., Kirkland, WA
- Nurotron Biotechnol. Inc., Irvine, CA
- Chinese Academy of Sciences (CN)
- Corresponding author
- Zeng, Fan-Gang
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2008
- Volume
- 1
- Pages
- 115-142
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- PMC
- PMC2782849
- OpenAlex
- W2112854909
- Cited by
- 878
- References
- 227
- Citations by year
- 2026: 60 · 2025: 75 · 2024: 65 · 2023: 62 · 2022: 57 · 2021: 79 · 2020: 69 · 2019: 70 · 2018: 50 · 2017: 48 · 2016: 44 · 2015: 39 · 2014: 43 · 2013: 40 · 2012: 27
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (HHS-N-263-2007-00054-C, 5r01dc008858-05)
- U.S. Public Health Service (HHSN-263-2007-00054C)
- National Institute on Deafness and Other Communication Disorders (P30DC008369, HHSN263200700054C, R01-DC008858, R01DC002267)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
- Keywords
- cochlear implants, neural prostheses, hearing loss, system design, radio frequency transmission, stimulator, electrode arrays, system integration, safety and reliability, functional assessment, pediatric cochlear implant users, vestibular implant, retinal prosthesis
- MeSH terms
- Animals, Cochlear Implants, Humans, Prosthesis Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review