Abstract
We present experimental results that investigate the integration of two disparate sensing modalities, force and vision, for sensor-based microassembly. By integrating these sensing modes, we are able to provide feedback in a task-oriented frame of reference over a broad range of motion with an extremely high precision. An optical microscope is used to provide visual feedback down to micron resolutions. We have developed an optical beam deflection sensor to provide nanonewton level force feedback or nanometric level position feedback. The value of integrating these two disparate sensing modalities is demonstrated during controlled micropart impact experiments. Using force feedback alone to control micropart contact transitions, impact forces of over 140 nN were generated before the desired contact force of 2 nN was achieved. When visual servoing is integrated with the force control framework, micropart impact forces of only 9 nN and final contact forces of 2 nN were easily achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 20
- martin, 1966, The Theory of the Microscope
- 10.1109/ICAR.1997.620191 · doi:10.1109/icar.1997.620191
- nelson, 1993, Visual Servoing Real-Time Control of Robot Manipulators Based on Visual Sensory Feedback, 139, 10.1142/9789814503709_0005 · doi:10.1142/9789814503709_0005
- 10.1109/ROBOT.1995.525361 · doi:10.1109/robot.1995.525361
- papanikolopoulos, 1991, adaptive robotic visual tracking, 1991 American Control Conference ACC, 962, 10.23919/ACC.1991.4791520 · doi:10.23919/acc.1991.4791520
- 10.1109/ISIC.1992.225102 · doi:10.1109/isic.1992.225102
- 10.1109/ROBOT.1995.525264 · DOI
- slocum, 1992, Precision Machine Design
- 10.1109/SENSOR.1997.613638 · doi:10.1109/sensor.1997.613638
- 10.1109/ROBOT.1997.606771 · doi:10.1109/robot.1997.606771
- 10.1109/IROS.1995.526162 · doi:10.1109/iros.1995.526162
- 10.1017/CBO9780511575013 · doi:10.1017/cbo9780511575013
- 10.1109/ROBOT.1997.614267 · doi:10.1109/robot.1997.614267
- 10.1116/1.577696 · doi:10.1116/1.577696
- 10.1063/1.1146080 · doi:10.1063/1.1146080
- hicks, 1997, The NanoPositioning Book
- 10.1109/IROS.1995.526166 · doi:10.1109/iros.1995.526166
- 10.1116/1.576520 · DOI · Paper page
- 10.1109/ROBOT.1996.506545 · doi:10.1109/robot.1996.506545
- 10.1109/ROBOT.1995.525360 · doi:10.1109/robot.1995.525360
Cited by
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
“[6] developed a force-sensing scheme relying on measuring the deflection of an optical beam.”
BackgroundApplied force during vitreoretinal microsurgery with handheld instruments
Jagtap, A. D., & Riviere, C. N. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403792 · Cited by 79
Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54
“For microassembly tasks, similar results were reported by Zhou et al [19].”
Result
Metadata
- Authors
- Zhou, Y., Nelson, B. J., & Vikramaditya, B.
- Venue
- Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146)
- Publisher
- IEEE
- Published
- 2002-11-27
- Volume
- 2
- Pages
- 1220-1225
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2127350763
- Cited by
- 90
- References
- 0
- FWCI
- 9.78
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.