Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 747

The DOI matches its Crossref record.

Microfabrication of cantilever styli for the atomic force microscope

Albrecht, T. R., Akamine, S., Carver, T. E., Quate, C. F.·1990·Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films

Abstract

Atomic force microscopy (AFM) is a newly developed high resolution microscopy technique which is capable of mapping forces near surfaces or, by means of these forces, the topography of the surface itself. In one mode of operation, AFM can resolve individual atoms on both conducting and insulating surfaces. A crucial component for the AFM is a flexible force-sensing cantilever stylus, whose properties should include, among other things: a sharp tip, a low force constant, and a high mechanical resonance frequency. These requirements can be met by reducing the size of the cantilever stylus through microfabrication techniques and employing novel methods to construct a sharp tip. Presented here are a number of microfabrication processes for constructing cantilever styli with properties ideal for the AFM. These fabrication processes include (1) a method for producing thin film SiO2 or Si3N4 cantilevers without tips, (2) a method for producing Si3N4 cantilevers with integrated pyramidal tips formed by using an etch pit on the (100) surface of Si as a mold, (3) a method for producing SiO2 cantilevers with conical tips formed by a combination of isotropic and anisotropic plasma etching of a small Si post, and (4) a method for producing SiO2 cantilevers with integrated tetrahedral tips formed by anisotropically etching a corner of a small Si post to a sharp point. Each of these processes uses a (100) Si wafer as a substrate and relies on conventional batch fabrication techniques. The quality (i.e., sharpness) of the tips produced by the above methods matches or exceeds that of conventional tips used in the AFM or scanning tunneling microscope (STM). Alternative methods for producing tips by evaporation of material through an orifice or by selective chemical vapor deposition of W metal into a pyramidal etch pit in Si have been demonstrated, but these methods have not yet been successfully used in cantilever assemblies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1116/1.576520

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 747

Metadata

Authors
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F.
Venue
Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films
Published
1990-07-01
Volume
8
Issue
4
Pages
3386-3396
ISSN
  • 0734-2101 (ISSN-L)
  • 1520-8559
OpenAlex
W2128193161
Cited by
747
References
0
FWCI
30.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfabrication of cantilever styli for the atomic force microscope. https://app.cochat.ai/papers/10.1116/1.576520
The paper
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990). Microfabrication of cantilever styli for the atomic force microscope. Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films. https://doi.org/10.1116/1.576520

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.