Force feedback-based microinstrument for measuring tissue properties and pulse in microsurgery
The DOI matches its Crossref record.
Abstract
Miniaturized and "smart" instruments capable of characterizing the mechanical properties of tiny biological tissues are needed for research in biology, physiology and biomechanics, and can find very important clinical applications for diagnostics and minimally invasive surgery (MIS). We are developing a set of robotic microinstruments designed to augment the performance of the surgeon during MIS. These microtools are intended to restore (or even enhance) the finger palpation capabilities that the surgeon exploits to characterize tissue hardness and to measure pulsating vessels in traditional surgery, but that are substantially reduced in MIS. The paper describes the main features and the performance of a prototype miniature robotic instrument consisting of a microfabricated microgripper, instrumented with semiconductor strain-gauges as force sensors. For the (in vitro) experiments reported in the paper, the microgripper is mounted on a workstation and teleoperated. A haptic interface provides force feedback to the operator. We have demonstrated that the system can discriminate tiny skin samples based on their different elastic properties, and feel microvessels based on pulsating fluid flowing through them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of force feedback in surgery: analysis of blunt dissection
Wagner, C. R., Stylopoulos, N., & Howe, R. D. (2005) · Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002 · doi:10.1109/haptic.2002.998943 · Cited by 379
Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis
Tholey, G., Desai, J. P., & Castellanos, A. E. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000149301.60553.1e · Cited by 330
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
The benefit of force feedback in surgery: Examination of blunt dissection
Wagner, C. R., Stylopoulos, N., Jackson, P. G., & Howe, R. D. (2007) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.16.3.252 · Cited by 169
“…of force-sensing surgical instruments (Berkelman, Whitcomb, Taylor, & Jensen, 2000; Biason, Boschetti, Gasparetto, Giovagnoni, & Zanotto, 2005; Menciassi et al., 2001; Morimoto et al., 1997; Tavakoli, Patel, & Moallem, 2005), and force feedback instruments (Cavusoglu, Sherman, & Tendick,…”
Applied force during vitreoretinal microsurgery with handheld instruments
Jagtap, A. D., & Riviere, C. N. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403792 · Cited by 79
Metadata
- Authors
- Menciassi, A., Eisinberg, A., Scalari, G., Anticoli, C., Carrozza, M. C., & Dario, P.
- Venue
- Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164)
- Publisher
- IEEE
- Published
- 2002-11-13
- Volume
- 1
- Pages
- 626-631
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2105161487
- Cited by
- 71
- References
- 0
- FWCI
- 4.93
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Force feedback-based microinstrument for measuring tissue properties and pulse in microsurgery. https://app.cochat.ai/papers/10.1109/robot.2001.932620
- The paper
- Menciassi, A., Eisinberg, A., Scalari, G., Anticoli, C., Carrozza, M. C., & Dario, P. (2002). Force feedback-based microinstrument for measuring tissue properties and pulse in microsurgery. Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164). https://doi.org/10.1109/robot.2001.932620
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.