The DOI matches its Crossref record.
Learning EMG control of a robotic hand: towards active prostheses
Open accessAbstract
We introduce a method based on support vector machines which can detect opening and closing actions of the human thumb, index finger, and other fingers recorded via surface EMG only. The method is shown to be robust across sessions and can be used independently of the position of the arm. With these stability criteria, the method is ideally suited for the control of active prosthesis with a high number of active degrees of freedom. The method is successfully demonstrated on a robotic four-finger hand, and can be used to grasp objects
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
Self-citationBuilding the Ninapro database: A resource for the biorobotics community
Atzori, M., Gijsberts, A., Heynen, S., Hager, A.-G. M., Deriaz, O., van der Smagt, P., Castellini, C., Caputo, B., & Muller, H. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290287 · Cited by 262
Self-citationSurface EMG pattern recognition for real-time control of a wrist exoskeleton
Khokhar, Z. O., Xiao, Z. G., & Menon, C. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-41 · Cited by 258
Tavakoli, M., Benussi, C., Alhais Lopes, P., Osorio, L. B., & de Almeida, A. T. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.07.010 · Cited by 173
Pang, M., Guo, S., Huang, Q., Ishihara, H., & Hirata, H. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0033-8 · Cited by 53
Metadata
- Authors
- Bitzer, S., & van der Smagt, P.
- Venue
- Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006.
- Publisher
- IEEE
- Published
- 2006-07-10
- Pages
- 2819-2823
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2141195300
- Cited by
- 245
- References
- 0
- FWCI
- 17.54
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.