A versatile wire robot concept as a haptic interface for sport simulation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents the design of a new user-cooperative rope robot. This robot serves as a large-scale haptic interface in a multi-modal Cave environment used for sport simulation. In contrast to current rope robots, the configuration of the presented robot is adaptable to different simulation tasks what makes the robot more versatile. However, this adaptability and the high dynamics in sports lead to challenging requirements and specific design criteria of the hardware components. We present the requirements on the single robot components as well as the design of the entire setup optimized in terms of user-cooperativity and versatility. The setup includes sensors to measure the relevant parameters for user-cooperative control, i.e. position with a high resolution and the rope forces. Furthermore, an algorithm is introduced, which calculates the distance between the single ropes and the user in order to avoid collisions between the ropes and the user. Single points on the user's body are, therefore, tracked with a motion tracking system; the user's single body parts are then represented by geometrical objects whose distances to the ropes are calculated. The algorithm is programmed in such way that the collision detection runs in real-time. Both, the hardware and the algorithm, were evaluated experimentally in two applications, a rowing simulator and a tennis application. The hardware concept combined with the distance calculation allows the use of new kinematic concepts and expands the spectrum of realizable movement tasks that can be implemented into the Cave environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“This redundant position measurement serves as a safety measure as it is often applied in user-cooperative devices [28], [ 29 ].”
Method
Cited by
Cable-driven parallel mechanisms: state of the art and perspectives
GOSSELIN, C. (2014) · Mechanical Engineering Reviews · doi:10.1299/mer.2014dsm0004 · Cited by 168
A tendon-based parallel robot applied to motor learning in sports
Rauter, G., von Zitzewitz, J., Duschau-Wicke, A., Vallery, H., & Riener, R. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5627788 · Cited by 41
Self-citationAssistance or challenge? Filling a gap in user-cooperative control
Rauter, G., Sigrist, R., Marchal-Crespo, L., Vallery, H., Riener, R., & Wolf, P. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094832 · Cited by 24
“The haptic display consists of a tendon-based parallel robot (TBPR) developed in our lab [19].”
MethodSelf-citationSynthesis and control of an assistive robotic tennis trainer
Marchal-Crespo, L., Rauter, G., Wyss, D., von Zitzewitz, J., & Riener, R. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290262 · Cited by 20
Self-citation
Metadata
- Authors
- v. Zitzewitz, J., Rauter, G., Steiner, R., Brunschweiler, A., & Riener, R.
- Venue
- 2009 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2009-05
- Pages
- 313-318
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2100514499
- Cited by
- 58
- References
- 1
- FWCI
- 16.31
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.