A comparison of muscle with artificial actuators
Abstract
'Artificial' actuator technologies under development include shape memory alloys, piezoelectric actuators, magnetostrictive actuators, contractile polymers and electrostatic actuators. The relevant properties of muscle are outlined and compared with a variety of artificial actuators. These and other actuators, such as regular and superconducting electromagnetic motors, internal combustion engines, hydraulic motors, pneumatic actuators, are reviewed and compared with muscle elsewhere (see Hunter, 1990; Hollerbach et al., 1991).>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial Muscles: Mechanisms, Applications, and Challenges
Mirvakili, S. M., & Hunter, I. W. (2018) · Advanced Materials · doi:10.1002/adma.201704407 · Cited by 1,077
Self-citationConducting polymer artificial muscles
Baughman, R. H. (1996) · Synthetic Metals · doi:10.1016/0379-6779(96)80158-5 · Cited by 870
High-field deformation of elastomeric dielectrics for actuators
Pelrine, R., Kornbluh, R., Joseph, J., Heydt, R., Pei, Q., & Chiba, S. (2000) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(00)00128-4 · Cited by 696
Kellaris, N., Gopaluni Venkata, V., Smith, G. M., Mitchell, S. K., & Keplinger, C. (2018) · Science Robotics · doi:10.1126/scirobotics.aar3276 · Cited by 554
Liquid‐Phase Metal Inclusions for a Conductive Polymer Composite
Fassler, A., & Majidi, C. (2015) · Advanced Materials · doi:10.1002/adma.201405256 · Cited by 409
Metadata
- Authors
- Hunter, I. W., & Lafontaine, S.
- Venue
- Technical Digest IEEE Solid-State Sensor and Actuator Workshop
- Publisher
- IEEE
- Published
- 2003-01-02
- Pages
- 178-185
- OpenAlex
- W1594060995
- Cited by
- 263
- References
- 0
- FWCI
- 18.01
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of muscle with artificial actuators. https://app.cochat.ai/papers/10.1109/solsen.1992.228297
- The paper
- Hunter, I. W., & Lafontaine, S. (2003). A comparison of muscle with artificial actuators. Technical Digest IEEE Solid-State Sensor and Actuator Workshop. https://doi.org/10.1109/solsen.1992.228297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.