A comparison of muscle with artificial actuators
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
'Artificial' actuator technologies under development include shape memory alloys, piezoelectric actuators, magnetostrictive actuators, contractile polymers and electrostatic actuators. The relevant properties of muscle are outlined and compared with a variety of artificial actuators. These and other actuators, such as regular and superconducting electromagnetic motors, internal combustion engines, hydraulic motors, pneumatic actuators, are reviewed and compared with muscle elsewhere (see Hunter, 1990; Hollerbach et al., 1991).>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1971) · Elsevier eBooks · doi:10.1016/b978-0-12-379550-2.x5001-7 · Cited by 2,732
Lovinger, A. J. (1983) · Science · doi:10.1126/science.220.4602.1115 · Cited by 1,939
Effect of Low-Temperature Phase Changes on the Mechanical Properties of Alloys near Composition TiNi
Buehler, W. J., Gilfrich, J. V., & Wiley, R. C. (1963) · Journal of Applied Physics · doi:10.1063/1.1729603 · Cited by 1,151
Tadaki, T., Otsuka, K., & Shimizu, K. (1988) · Annual Review of Materials Science · doi:10.1146/annurev.ms.18.080188.000325 · Cited by 1,030
The identification of nonlinear biological systems: Wiener and Hammerstein cascade models
Hunter, I. W., & Korenberg, M. J. (1986) · Biological Cybernetics · doi:10.1007/bf00341929 · Cited by 639
Self-citationKUHN, W., HARGITAY, B., KATCHALSKY, A., & EISENBERG, H. (1950) · Nature · doi:10.1038/165514a0 · Cited by 490
Electrostatics and its applications
Moore, A. D. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 441
System identification of human joint dynamics.
Kearney, R. E., & Hunter, I. (1990) · PubMed · Cited by 425
Self-citationA comparative analysis of actuator technologies for robotics
Hollerbach, J. M., Hunter, I. W., & Ballantyne, J. (1992) · The MIT Press eBooks · Cited by 402
Self-citationSub-piconewton force fluctuations of actomyosin in vitro
Ishijima, A., Doi, T., Sakurada, K., & Yanagida, T. (1991) · Nature · doi:10.1038/352301a0 · Cited by 272
Cited by
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Advances in Dielectric Elastomers for Actuators and Artificial Muscles
Brochu, P., & Pei, Q. (2010) · Macromolecular Rapid Communications · doi:10.1002/marc.200900425 · Cited by 1,387
Artificial Muscles: Mechanisms, Applications, and Challenges
Mirvakili, S. M., & Hunter, I. W. (2018) · Advanced Materials · doi:10.1002/adma.201704407 · Cited by 1,077
Self-citationArtificial Muscle Technology: Physical Principles and Naval Prospects
Madden, J. D. W., Vandesteeg, N. A., Anquetil, P. A., Madden, P. G. A., Takshi, A., Pytel, R. Z., Lafontaine, S. R., Wieringa, P. A., & Hunter, I. W. (2004) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2004.833135 · Cited by 1,035
Self-citationShahinpoor, M., Bar-Cohen, Y., Simpson, J. O., & Smith, J. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/6/001 · Cited by 1,021
Conducting polymer artificial muscles
Baughman, R. H. (1996) · Synthetic Metals · doi:10.1016/0379-6779(96)80158-5 · Cited by 870
High-field deformation of elastomeric dielectrics for actuators
Pelrine, R., Kornbluh, R., Joseph, J., Heydt, R., Pei, Q., & Chiba, S. (2000) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(00)00128-4 · Cited by 696
Kellaris, N., Gopaluni Venkata, V., Smith, G. M., Mitchell, S. K., & Keplinger, C. (2018) · Science Robotics · doi:10.1126/scirobotics.aar3276 · Cited by 554
Thin film shape memory alloy microactuators
Krulevitch, P., Lee, A. P., Ramsey, P. B., Trevino, J. C., Hamilton, J., & Northrup, M. A. (1996) · Journal of Microelectromechanical Systems · doi:10.1109/84.546407 · Cited by 529
New materials for micro-scale sensors and actuators
Wilson, S. A., Jourdain, R. P. J., Zhang, Q., Dorey, R. A., Bowen, C. R., Willander, M., Wahab, Q. U., Willander, M., Al-hilli, S. M., Nur, O., et al. (2007) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.03.001 · Cited by 514
Electronic Muscles and Skins: A Review of Soft Sensors and Actuators
Chen, D., & Pei, Q. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00019 · Cited by 506
Wensing, P. M., Wang, A., Seok, S., Otten, D., Lang, J., & Kim, S. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2640183 · Cited by 472
Liquid‐Phase Metal Inclusions for a Conductive Polymer Composite
Fassler, A., & Majidi, C. (2015) · Advanced Materials · doi:10.1002/adma.201405256 · Cited by 409
Design and Control Considerations for High-Performance Series Elastic Actuators
Paine, N., Oh, S., & Sentis, L. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2270435 · Cited by 405
Review of biomimetic underwater robots using smart actuators
Chu, W.-S., Lee, K.-T., Song, S.-H., Han, M.-W., Lee, J.-Y., Kim, H.-S., Kim, M.-S., Park, Y.-J., Cho, K.-J., & Ahn, S.-H. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0171-7 · Cited by 359
Microfabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344
Carbon Nanotube and Graphene‐based Bioinspired Electrochemical Actuators
Kong, L., & Chen, W. (2014) · Advanced Materials · doi:10.1002/adma.201303432 · Cited by 307
Highly Stretchable and Self‐Deformable Alternating Current Electroluminescent Devices
Wang, J., Yan, C., Chee, K. J., & Lee, P. S. (2015) · Advanced Materials · doi:10.1002/adma.201405486 · Cited by 289
Lu, H.-F., Wang, M., Chen, X.-M., Lin, B.-P., & Yang, H. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b06757 · Cited by 287
Ophthalmic microsurgical robot and associated virtual environment
Hunter, I. W., Jones, L. A., Sagar, M. A., Lafontaine, S. R., & Hunter, P. J. (1995) · Computers in Biology and Medicine · doi:10.1016/0010-4825(94)00042-o · Cited by 70
Self-citation
Metadata
- Authors
- Hunter, I. W., & Lafontaine, S.
- Venue
- Technical Digest IEEE Solid-State Sensor and Actuator Workshop
- Publisher
- IEEE
- Published
- 2003-01-02
- Pages
- 178-185
- OpenAlex
- W1594060995
- Cited by
- 263
- References
- 23
- FWCI
- 18.01
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.