The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Pressure sensitivity in anisotropically etched thin-diaphragm pressure sensors
Abstract
In this paper the differential equations governing thin, square-diaphragm silicon pressure sensors are developed and solved using finite-difference numerical methods. Diaphragm deflection and stress patterns are presented in a normalized form applicable to diaphragms of arbitrary thickness and size. For 1-mm210-µm-thick diaphragms in
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
Foundations of solid mechanics
Pohle, F. V. (1966) · Journal of the Franklin Institute · doi:10.1016/0016-0032(66)90243-2 · Cited by 1,950
Transport Properties of a Many-Valley Semiconductor
Herring, C. (1955) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1955.tb01472.x · Cited by 544
Formulas for stress and strain
Roark, R. J. (1965) · CERN Document Server (European Organization for Nuclear Research) · Cited by 328
Silicon Diffused-Element Piezoresistive Diaphragms
Tufte, O. N., Chapman, P. W., & Long, D. (1962) · Journal of Applied Physics · doi:10.1063/1.1931164 · Cited by 267
An IC Piezoresistive Pressure Sensor for Biomedical Instrumentation
Samaun, Wise, K. D., & Angell, J. B. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324170 · Cited by 158
Self-citationNoyce, R. N. (1977) · Scientific American · doi:10.1038/scientificamerican0977-62 · Cited by 123
A Microminiature Solid-State Capacitive Blood Pressure Transducer with Improved Sensitivity
Frobenius, W. D., Sanderson, A., & Nathanson, H. C. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324204 · Cited by 35
Sadd, M. H. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-408136-9.00011-8 · Cited by 4
Cited by
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Review: Semiconductor Piezoresistance for Microsystems
Barlian, A. A., Park, W.-T., Mallon, J. R., Rastegar, A. J., & Pruitt, B. L. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2013612 · Cited by 949
Micromachined pressure sensors: review and recent developments
Eaton, W. P., & Smith, J. H. (1997) · Smart Materials and Structures · doi:10.1088/0964-1726/6/5/004 · Cited by 593
Electromechanical Piezoresistive Sensing in Suspended Graphene Membranes
Smith, A. D., Niklaus, F., Paussa, A., Vaziri, S., Fischer, A. C., Sterner, M., Forsberg, F., Delin, A., Esseni, D., Palestri, P., et al. (2013) · Nano Letters · doi:10.1021/nl401352k · Cited by 413
Capacitive sensors: When and how to use them
Puers, R. (1993) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(93)80019-d · Cited by 333
Metadata
- Authors
- Clark, S. K., & Wise, K. D.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 1979-12
- Volume
- 26
- Issue
- 12
- Pages
- 1887-1896
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W1974978401
- Cited by
- 301
- References
- 9
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.