A monolithic capacitive pressure sensor with pulse-period output
The DOI matches its Crossref record.
Abstract
A new microminiature monolithic capacitive pressure transducer (CPT I) is 20 times more sensitive than piezoresistive strain-gauge pressure transducers, requires one percent of the power, and can be batch fabricated through current integrated circuit technology. A second device (CPT II) incorporates bipolar signal-processing electronics on the same silicon chip to produce a low-duty-cycle pulse-mode output with period related to pressure. This output format helps to re-solve the problem of shunting between leads, which is one of the principal causes of long-term drift in piezoresistive transducers designed for implantable medical applications. Because this device uses capacitance change as a transductional mechanism rather than piezo-resistivity, it is not susceptible to drift caused by temperature variations in the piezoresistive coefficient. Optimization for totally implantable biomedical applications places special emphasis on small size, high sensitivity, improved long-term baseline stability, and greatly reduced power consumption. These properties are also important for a wide range of pressure-sensing applications-from automotive to general industrial use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Micromachined pressure sensors: review and recent developments
Eaton, W. P., & Smith, J. H. (1997) · Smart Materials and Structures · doi:10.1088/0964-1726/6/5/004 · Cited by 593
Capacitive sensors: When and how to use them
Puers, R. (1993) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(93)80019-d · Cited by 333
Bai, P., Zhu, G., Jing, Q., Yang, J., Chen, J., Su, Y., Ma, J., Zhang, G., & Wang, Z. L. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201401267 · Cited by 282
Recent Progress of Miniature MEMS Pressure Sensors
Song, P., Ma, Z., Ma, J., Yang, L., Wei, J., Zhao, Y., Zhang, M., Yang, F., & Wang, X. (2020) · Micromachines · doi:10.3390/mi11010056 · Cited by 262
A Path Beyond Metal and Silicon:Polymer/Nanomaterial Composites for Stretchable Strain Sensors
Qiu, A., Li, P., Yang, Z., Yao, Y., Lee, I., & Ma, J. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806306 · Cited by 237
Microsensor Integration Into Systems-on-Chip
Brand, O. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.873618 · Cited by 106
“Shortly thereafter, the first integrated capacitive pressure sensor with bipolar circuitry has been demonstrated [ 55 ].”
Method
Metadata
- Authors
- Sander, C. S., Knutti, J. W., & Meindl, J. D.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 1980-05
- Volume
- 27
- Issue
- 5
- Pages
- 927-930
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2050281778
- Cited by
- 190
- References
- 0
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.