A monolithic capacitive pressure sensor with pulse-period output

Sander, C.S., Knutti, J.W., Meindl, J.D. · 1980 · IEEE Transactions on Electron Devices
Cited by 190

The DOI matches its Crossref record.

Abstract

A new microminiature monolithic capacitive pressure transducer (CPT I) is 20 times more sensitive than piezoresistive strain-gauge pressure transducers, requires one percent of the power, and can be batch fabricated through current integrated circuit technology. A second device (CPT II) incorporates bipolar signal-processing electronics on the same silicon chip to produce a low-duty-cycle pulse-mode output with period related to pressure. This output format helps to re-solve the problem of shunting between leads, which is one of the principal causes of long-term drift in piezoresistive transducers designed for implantable medical applications. Because this device uses capacitance change as a transductional mechanism rather than piezo-resistivity, it is not susceptible to drift caused by temperature variations in the piezoresistive coefficient. Optimization for totally implantable biomedical applications places special emphasis on small size, high sensitivity, improved long-term baseline stability, and greatly reduced power consumption. These properties are also important for a wide range of pressure-sensing applications-from automotive to general industrial use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/t-ed.1980.19958

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sander, C. S., Knutti, J. W., & Meindl, J. D.
Venue
IEEE Transactions on Electron Devices
Published
1980-05
Volume
27
Issue
5
Pages
927-930
ISSN
  • 0018-9383 (ISSN-L)
  • 1557-9646
OpenAlex
W2050281778
Cited by
190
References
0
FWCI
8.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.