The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Statistics of Speckle in Ultrasound B-Scans
Abstract
the of the magnitude, i.e., intensity, of the field.) It is shown that Rayleigh statistics govern the fist-order behavior of the magnitude; and the autocorrelation of the resulting image speckle is obtained by the methodof Middleton. The corresponding power spectrum follows immediately by Fourier transformation. Theoretical and experimentally determined autocorrelation functions and power spectra derived from B-scans of a scattering phantom containing many scatterers per resolution cell are presented. These functions lead naturally to the definition of the average speckle spot or cell sue, and this inturn is comparable to the resolution cell. Each independent speckle servesas a degreeof freedom that determines the number of samples of tissue available over a target.As the speckle cell size decreases this number increases in a manner predictable from the physical parameters of the cell size. However, it is found that the speckle cellis broadened, the degrees of freedom diminished, when the object structureis correlated. This yields the possibilityof deducing information about the object structure from the second-order statistics of the speckle texture, in addition to that obtainable from the fiistorder statistics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Handbook of Mathematical Functions
(2018) · A Century of Excellence in MEASUREMENTS, STANDARDS, and TECHNOLOGY · doi:10.1201/9781351069397-39 · Cited by 9,062
Probability, Random Variables, and Stochastic Processes
Miller, I. (1966) · Technometrics · doi:10.1080/00401706.1966.10490365 · Cited by 8,452
Mathematical Analysis of Random Noise
Rice, S. O. (1944) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1944.tb00874.x · Cited by 5,480
Random variables and stochastic processes
Larson, H. J., & Shubert, B. O. (1979) · Wiley eBooks · Cited by 4,640
Statistical Properties of Laser Speckle Patterns
Goodman, J. W. (1975) · Topics in Applied Physics · doi:10.1007/978-3-662-43205-1_2 · Cited by 1,249
An Introduction to Statistical Communication Theory
Middleton, D. (2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544112.part1 · Cited by 1,127
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
An introduction to statistical communication theory
Siebert, W. M. (1961) · Journal of the Franklin Institute · doi:10.1016/0016-0032(61)90153-3 · Cited by 703
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
“It has been shown that the statistical properties of the received signal, and thus of the echo envelope, depend on the density and the spatial distribution of the scatters [174].”
BackgroundInfluentialSasso, M., Beaugrand, M., de Ledinghen, V., Douvin, C., Marcellin, P., Poupon, R., Sandrin, L., & Miette, V. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.005 · Cited by 862
Measurement of Ventricular Torsion by Two-Dimensional Ultrasound Speckle Tracking Imaging
Notomi, Y., Shiota, T., Popović, Z. B., Weaver, J. A., Oryszak, S. J., Greenberg, N. L., White, R. D., Thomas, J. D., Setser, R. M., White, R. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.082 · Cited by 767
A versatile wavelet domain noise filtration technique for medical imaging
Pizurica, A., Philips, W., Lemahieu, I., & Acheroy, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809588 · Cited by 531
A general statistical model for ultrasonic backscattering from tissues
Mohana Shankar, P. (2000) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.842062 · Cited by 529
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
Oriented Speckle Reducing Anisotropic Diffusion
Krissian, K., Westin, C.-F., Kikinis, R., & Vosburgh, K. G. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.891803 · Cited by 377
Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
Loizou, C. P., Pattichis, C. S., Christodoulou, C. I., Istepanian, R. S. H., Pantziaris, M., & Nicolaides, A. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561621 · Cited by 323
Hein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
Removing Multiplicative Noise by Douglas-Rachford Splitting Methods
Steidl, G., & Teuber, T. (2010) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-009-0179-5 · Cited by 287
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Kadah, Y. M., Farag, A. A., Zurada, J. M., Badawi, A. M., & Youssef, A.-B. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511750 · Cited by 265
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
A hierarchical model for automatic nuchal translucency detection from ultrasound images
Deng, Y., Wang, Y., Chen, P., & Yu, J. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.04.002 · Cited by 31
Metadata
- Authors
- Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H.
- Venue
- IEEE Transactions on Sonics and Ultrasonics
- Published
- 1983-05
- Volume
- 30
- Issue
- 3
- Pages
- 156-163
- ISSN
- 0018-9537 (ISSN-L)
- OpenAlex
- W2171857449
- Cited by
- 1,398
- References
- 15
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.