Abstract

The paper deals with the problem of controlling artificial limbs in cases where several limb functions require control. These situations are of importance, especially to above-elbow upper-extremity amputees. Here, classical EMG (myoelectric) controllers have failed in the past, since they were based on only determining existence or nonexistence of an EMG signal. Recent work by Lyman et al. at UCLA has approached this multifunctional (MF) control problem via using a large number of electrodes, though still considering only a limited part of the EMG spectrum. The present approach is based on earlier work by Graupe et al. [4], considering the whole spectrum of the EMG signal via identifying its time series model such that several limb functions can be controlled from a single signal site. However, the present work subsequently employs parallel filtering to discriminate between the various limb functions of interest to achieve fast discrimination and control as required for practical applications, since this allows the identification itself to be performed off line. Real-time on-line results are presented in the paper, as recently obtained from tests carried out on a 1969 Vietnam above-elbow amputee who had most severe (90 percent) nerve and muscle loss at his stump, and could therefore not use more than one or two electrode pairs. The results, where complete discrimination was achieved within 0.15 to 0.2 seconds using 8-bit Intel 8080 microprocessors at double precision (incorporating hardware multipliers), have yielded an 85 percent success rate in discrimination between four to five limb functions using a single electrode pair. It is noted that the amputee mentioned had no previous EMG actuation training whatsoever.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tac.1978.1101783

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 154

Metadata

Authors
Graupe, D., Magnussen, J., & Beex, A.
Venue
IEEE Transactions on Automatic Control
Published
1978-08
Volume
23
Issue
4
Pages
538-544
ISSN
0018-9286 (ISSN-L)
OpenAlex
W2089818272
Cited by
154
References
1
FWCI
4.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.