Best tracking and regulation performance under control energy constraint
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This paper studies optimal tracking and regulation control problems, in which objective functions of tracking error and regulated response, defined by integral square measures, are to be minimized jointly with the control effort, where the latter is measured by the plant input energy. Our primary objective in this work is to search for fundamental design limitations beyond those known to be imposed by nonminimum phase zeros, unstable poles, and time delays. For this purpose, we solve the problems explicitly by deriving analytical expressions for the best achievable performance. It is found that this performance limit depends not only on the plant nonminimum phase zeros, time delays, and unstable poles-a fact known previously-but also on the plant gain in the entire frequency range. The results thus reveal and quantify another source of fundamental performance limitations beyond those already known, which are nonexistent when only conventional performance objectives such as tracking and regulation are addressed without taking into account the control energy constraint. Among other things, they exhibit how the lightly damped poles, the anti-resonant zeros, as well as the bandwidth of the plant may affect the performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Linear Optimal Control Systems
Kwakernaak, H., Sivan, R., & Tyreus, B. N. D. (1974) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3426828 · Cited by 4,976
Virk, G. S. (1990) · Chemical Engineering Science · doi:10.1016/0009-2509(90)85041-b · Cited by 3,216
Lewis, F. L. (1986) · Cited by 2,948
Morari, M., & Zafiriou, E. (1988) · International Linear Collider · Cited by 2,735
(1987) · Lecture Notes in Control and Information Sciences · doi:10.1007/bfb0007371 · Cited by 2,518
Control system synthesis: A factorization approach
(1986) · Automatica · doi:10.1016/0005-1098(86)90022-1 · Cited by 2,169
A Unified Algebraic Approach To Control Design
Grigoriadis, D. E. (2017) · Routledge eBooks · doi:10.1201/9781315136523 · Cited by 932
Fundamental Limitations in Filtering and Control
Seron, M. M., Braslavsky, J. H., & Goodwin, G. C. (1997) · Communications and Control Engineering · doi:10.1007/978-1-4471-0965-5 · Cited by 664 · cited 2×
“N RECENT years, there has been growing attention devoted to the studies of intrinsic performance limits achievable by feedback control (see, e.g., [ 21 ], [4], and the references therein).”
BackgroundRight half plane poles and zeros and design tradeoffs in feedback systems
Freudenberg, J. S., & Looze, D. P. (1985) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1985.1104004 · Cited by 636
Frequency Domain Properties of Scalar and Multivariable Feedback Systems
(1988) · Lecture Notes in Control and Information Sciences · doi:10.1007/bfb0044565 · Cited by 362
Cited by
Path-following for nonminimum phase systems removes performance limitations
Aguiar, A. P., Hespanha, J. P., & Kokotovic, P. V. (2005) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2004.841924 · Cited by 218
“Control energy constraints as another source of fundamental performance limitations have been investigated in [21].”
BackgroundJiang, X., Li, J., Li, B., Wang, Y.-W., & Huang, T. (2024) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2024.3388296 · Cited by 24
Metadata
- Authors
- Chen, J., Hara, S., & Chen, G.
- Venue
- IEEE Transactions on Automatic Control
- Published
- 2003-08
- Volume
- 48
- Issue
- 8
- Pages
- 1320-1336
- ISSN
- 0018-9286 (ISSN-L)
- OpenAlex
- W2560921213
- Cited by
- 161
- References
- 14
- FWCI
- 20.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Best tracking and regulation performance under control energy constraint. https://app.cochat.ai/papers/10.1109/tac.2003.815012
- The paper
- Chen, J., Hara, S., & Chen, G. (2003). Best tracking and regulation performance under control energy constraint. IEEE Transactions on Automatic Control. https://doi.org/10.1109/tac.2003.815012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.