Extension of a two-step calibration methodology to include nonorthogonal sensor axes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present an extension of the nonlinear two-step estimation algorithm originally developed for the calibration of solid-state strapdown magnetometers. We expand the algorithm to include nonorthogonality within a sensor set for both two- and three-axis sensors. Nonorthogonality can result from manufacturing issues, installation geometry, and in the case of magnetometers, from soft iron bias errors. Simulation studies for both two- and three-axis sensors show convergence of the improved algorithm to the true values, even in the presence of realistic measurement noise. Finally the algorithm is experimentally validated on a low-cost solid-state three-axis magnetometer set, which shows definite improvement postcalibration. We note that the algorithm is general and can be applied to any two- or three-axis sensor set (such as accelerometers) with an error model consisting of scale, offset, and nonorthogonality errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of Strapdown Magnetometers in Magnetic Field Domain
Gebre-Egziabher, D., Elkaim, G. H., David Powell, J., & Parkinson, B. W. (2006) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2006)19:2(87 · Cited by 326 · cited 3×
“For a full treatment of the method, including simulated and experimental results, see [6], [3].”
BackgroundMethodSelf-citationGebre-Egziabher, D., Elkaim, G. H., Powell, J. D., & Parkinson, B. W. (2002) · IEEE 2000. Position Location and Navigation Symposium (Cat. No.00CH37062) · doi:10.1109/plans.2000.838301 · Cited by 164 · cited 2×
“For a full treatment of the method, including simulated and experimental results, see [6], [3].”
MethodSelf-citationRevision of International Geomagnetic Reference Field released
IAGA Division V, W. G. 8. (1996) · Eos · doi:10.1029/96eo00106 · Cited by 34
Cited by
Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame
Vasconcelos, J. F., Elkaim, G., Silvestre, C., Oliveira, P., & Cardeira, B. (2011) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2011.5751259 · Cited by 318
Self-citationA wearable system for gait training in subjects with Parkinson's disease
Casamassima, F., Ferrari, A., Milosevic, B., Ginis, P., Farella, E., & Rocchi, L. (2014) · Sensors · doi:10.3390/s140406229 · Cited by 131
“Calibration methods for inertial and magnetic sensors are well documented [28,29].”
Method
Metadata
- Authors
- Foster, C. C., & Elkaim, G. H.
- Venue
- IEEE Transactions on Aerospace and Electronic Systems
- Published
- 2008-07
- Volume
- 44
- Issue
- 3
- Pages
- 1070-1078
- ISSN
- 0018-9251 (ISSN-L)
- OpenAlex
- W2163623431
- Cited by
- 223
- References
- 3
- FWCI
- 12.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.