The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame
Abstract
In this work a new algorithm is derived for the onboard calibration of three-axis strapdown magnetometers. The proposed calibration method is written in the sensor frame, and compensates for the combined effect of all linear time-invariant distortions, namely soft iron, hard iron, sensor nonorthogonality, and bias, among others. A maximum likelihood estimator (MLE) is formulated to iteratively find the optimal calibration parameters that best fit to the onboard sensor readings, without requiring external attitude references. It is shown that the proposed calibration technique is equivalent to the estimation of a rotation, scaling and translation transformation, and that the sensor alignment matrix is given by the solution of the orthogonal Procrustes problem. Good initial conditions for the iterative algorithm are obtained by a suboptimal batch least squares computation. Simulation and experimental results with low-cost sensors data are presented and discussed, supporting the application of the algorithm to autonomous vehicles and other robotic platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertsekas, D. P. (1997) · Journal of the Operational Research Society · doi:10.1038/sj.jors.2600425 · Cited by 11,726
Fundamentals of statistical signal processing: Estimation theory
Prasad, K. V. (1994) · Control Engineering Practice · doi:10.1016/0967-0661(94)90195-3 · Cited by 7,902
Fundamentals Of Statistical Signal Processing
Kay, S. (2001) · International Linear Collider · Cited by 3,642
The Geometry of Algorithms with Orthogonality Constraints
Edelman, A., Arias, T. A., & Smith, S. T. (1998) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/s0895479895290954 · Cited by 2,685
Weik, M. H. (2000) · Computer Science and Communications Dictionary · doi:10.1007/1-4020-0613-6_12436 · Cited by 2,570
Linear algebra and its applications
(1989) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(89)90164-x · Cited by 2,001
(2018) · De Gruyter eBooks · doi:10.1515/9783110542400 · Cited by 1,876
A Least Squares Estimate of Satellite Attitude
Wahba, G. (1965) · SIAM Review · doi:10.1137/1007077 · Cited by 1,116
Lütkepohl, H. (1996) · Cited by 923
Least-squares fitting of circles and ellipses
Gander, W., Golub, G. H., & Strebel, R. (1994) · BIT · doi:10.1007/bf01934268 · Cited by 860
Cited by
Using Inertial Sensors for Position and Orientation Estimation
Kok, M., Hol, J. D., & Schön, T. B. (2017) · Foundations and Trends® in Signal Processing · doi:10.1561/2000000094 · Cited by 347
Complete Triaxis Magnetometer Calibration in the Magnetic Domain
Renaudin, V., Afzal, M. H., & Lachapelle, G. (2010) · Journal of Sensors · doi:10.1155/2010/967245 · Cited by 286
Magnetometer Calibration Using Inertial Sensors
Kok, M., & Schon, T. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2569160 · Cited by 175
Metadata
- Authors
- Vasconcelos, J. F., Elkaim, G., Silvestre, C., Oliveira, P., & Cardeira, B.
- Venue
- IEEE Transactions on Aerospace and Electronic Systems
- Published
- 2011-04
- Volume
- 47
- Issue
- 2
- Pages
- 1293-1306
- ISSN
- 0018-9251 (ISSN-L)
- OpenAlex
- W2140257642
- Cited by
- 318
- References
- 19
- FWCI
- 37.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame. https://app.cochat.ai/papers/10.1109/taes.2011.5751259
- The paper
- Vasconcelos, J. F., Elkaim, G., Silvestre, C., Oliveira, P., & Cardeira, B. (2011). Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame. IEEE Transactions on Aerospace and Electronic Systems. https://doi.org/10.1109/taes.2011.5751259
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.