The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Complete Triaxis Magnetometer Calibration in the Magnetic Domain
Open accessAbstract
This paper presents an algorithm for calibrating erroneous tri-axis magnetometers in the magnetic field domain. Unlike existing algorithms, no simplification is made on the nature of errors to ease the estimation. A complete error model, including instrumentation errors (scale factors, nonorthogonality, and offsets) and magnetic deviations (soft and hard iron) on the host platform, is elaborated. An adaptive least squares estimator provides a consistent solution to the ellipsoid fitting problem and the magnetometer's calibration parameters are derived. The calibration is experimentally assessed with two artificial magnetic perturbations introduced close to the sensor on the host platform and without additional perturbation. In all configurations, the algorithm successfully converges to a good estimate of the said errors. Comparing the magnetically derived headings with a GNSS/INS reference, the results show a major improvement in terms of heading accuracy after the calibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct least square fitting of ellipses
Fitzgibbon, A., Pilu, M., & Fisher, R. B. (1999) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.765658 · Cited by 2,752
Stoer, J. (1999) · Springer-Lehrbuch · doi:10.1007/978-3-662-09021-3 · Cited by 2,059
Statistical Regression With Measurement Error
Gupta, S. (2000) · Technometrics · doi:10.1080/00401706.2000.10485717 · Cited by 500
Calibration of Strapdown Magnetometers in Magnetic Field Domain
Gebre-Egziabher, D., Elkaim, G. H., David Powell, J., & Parkinson, B. W. (2006) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2006)19:2(87 · Cited by 326
Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame
Vasconcelos, J. F., Elkaim, G., Silvestre, C., Oliveira, P., & Cardeira, B. (2011) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2011.5751259 · Cited by 318
A Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame
Vasconcelos, J. F., Elkaim, G., Silvestre, C., Oliveira, P., & Cardeira, B. (2008) · IFAC Proceedings Volumes · doi:10.3182/20080408-3-ie-4914.00031 · Cited by 82
Consistent least squares fitting of ellipsoids
Markovsky, I., Kukush, A. G., & Huffel, S. V. (2004) · Numerische Mathematik · doi:10.1007/s00211-004-0526-9 · Cited by 72
Automated system for the calibration of magnetometers
Petrucha, V., Kašpar, P., Ripka, P., et al. (2009) · Journal of Applied Physics · doi:10.1063/1.3062961 · Cited by 40
Cited by
Magnetometer Calibration Using Inertial Sensors
Kok, M., & Schon, T. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2569160 · Cited by 175
Metadata
- Authors
- Renaudin, V., Afzal, M. H., & Lachapelle, G.
- Venue
- Journal of Sensors
- Publisher
- Wiley
- Published
- 2010
- Volume
- 2010
- Pages
- 1-10
- ISSN
- 1687-725X (ISSN-L)
- 1687-7268
- OpenAlex
- W2146799968
- Cited by
- 286
- References
- 8
- FWCI
- 13.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complete Triaxis Magnetometer Calibration in the Magnetic Domain. https://app.cochat.ai/papers/10.1155/2010/967245
- The paper
- Renaudin, V., Afzal, M. H., & Lachapelle, G. (2010). Complete Triaxis Magnetometer Calibration in the Magnetic Domain. Journal of Sensors. https://doi.org/10.1155/2010/967245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.