Matrix of Integrated Superconducting Single-Photon Detectors With High Timing Resolution
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We demonstrate a large grid of individually addressable superconducting single photon detectors on a single chip. Each detector element is fully integrated into an independent waveguide circuit with custom functionality at telecom wavelengths. High device density is achieved by fabricating the nanowire detectors in traveling wave geometry directly on top of silicon-on-insulator waveguides. Our superconducting single photon detector matrix includes detector designs optimized for high detection efficiency, low dark count rate, and high timing accuracy. As an example, we exploit the high timing resolution of a particularly short nanowire design to resolve individual photon round-trips in a cavity ring-down measurement of a silicon ring resonator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597 · cited 1×
“eading to significantly increased absorption for much shorter overall wire length as compared to a meander-type SSPDs. The detection mechanism happens on picosecond timescales and is highly efficient [13]. In our case high photon absorption efficiency therefore directly translates to an increase in onchip detection ef…”
BackgroundSelf-citationO'Brien, J. L. (2007) · Science · doi:10.1126/science.1142892 · Cited by 1,221 · cited 2×
“The integration of nanophotonic circuits with large numbers of customizable detector designs on a scalable platform will allow for satisfying many of the needs of the quantum information and photonics community [1].”
BackgroundQuantum Walks of Correlated Photons
Peruzzo, A., Lobino, M., Matthews, J. C. F., Matsuda, N., Politi, A., Poulios, K., Zhou, X.-Q., Lahini, Y., Ismail, N., Wörhoff, K., et al. (2010) · Science · doi:10.1126/science.1193515 · Cited by 929
Superconducting nanowire photon-number-resolving detector at telecommunication wavelengths
Divochiy, A., Marsili, F., Bitauld, D., Gaggero, A., Leoni, R., Mattioli, F., Korneev, A., Seleznev, V., Kaurova, N., Minaeva, O., et al. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.51 · Cited by 406 · cited 2×
“Variable photon delay on-chip, as demonstrated here with Si-microring resonators, has interesting applications in feed-forward schemes [14] and for photon number resolving detection [15].”
BackgroundSelf-citationPoliti, A., Matthews, J., Thompson, M. G., & O'Brien, J. L. (2009) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2026060 · Cited by 196
Bonneau, D., Lobino, M., Jiang, P., Natarajan, C. M., Tanner, M. G., Hadfield, R. H., Dorenbos, S. N., Zwiller, V., Thompson, M. G., & O’Brien, J. L. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.053601 · Cited by 99 · cited 2×
“Variable photon delay on-chip, as demonstrated here with Si-microring resonators, has interesting applications in feed-forward schemes [14] and for photon number resolving detection [15].”
Background
Cited by
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Generation and sampling of quantum states of light in a silicon chip
Paesani, S., Ding, Y., Santagati, R., Chakhmakhchyan, L., Vigliar, C., Rottwitt, K., Oxenløwe, L. K., Wang, J., Thompson, M. G., & Laing, A. (2019) · Nature Physics · doi:10.1038/s41567-019-0567-8 · Cited by 214
Waveguide-integrated superconducting nanowire single-photon detectors
Ferrari, S., Schuck, C., & Pernice, W. (2017) · Nanophotonics · doi:10.1515/nanoph-2018-0059 · Cited by 167
Self-citationKahl, O., Ferrari, S., Kovalyuk, V., Goltsman, G. N., Korneev, A., & Pernice, W. H. P. (2015) · Scientific Reports · doi:10.1038/srep10941 · Cited by 102
Self-citationQuantum interference in heterogeneous superconducting-photonic circuits on a silicon chip
Schuck, C., Guo, X., Fan, L., Ma, X., Poot, M., & Tang, H. X. (2016) · Nature Communications · doi:10.1038/ncomms10352 · Cited by 86
Self-citation
Metadata
- Authors
- Schuck, C., Pernice, W. H. P., Minaeva, O., Li, M., Gol'tsman, G., Sergienko, A. V., & Tang, H. X.
- Venue
- IEEE Transactions on Applied Superconductivity
- Published
- 2013-06
- Volume
- 23
- Issue
- 3
- Pages
- 2201007-2201007
- ISSN
- 1051-8223 (ISSN-L)
- 1558-2515
- OpenAlex
- W2148871905
- Cited by
- 17
- References
- 6
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.