Cited by 21Prosthetics and Rehabilitation RoboticsMuscle activation and electromyography studiesHuman Motion and Animation

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.

Robust Sensor Fusion and Biomimetic Control of a Lower-Limb Exoskeleton With Multimodal Sensors

Arceo, Juan Carlos, Yu, Lingzhou, Bai, Shaoping·2025·IEEE Transactions on Automation Science and Engineering

Abstract

This article presents a systematic approach to robustly control a lower-limb exoskeleton in real-time using multimodal sensors. The control adopts two sensor bands that combine an array of force-sensitive resistors (FSR) and an inertial measurement unit (IMU) to measure both force myography (FMG) signals and limb motion. A robust sensor fusion algorithm that combines FMG and IMU signals with artificial neural networks is developed to accurately estimate the wearer’s hip and knee rotation angles. Moreover, a mathematical model of the lower-limb exoskeleton is calibrated and validated with real-time experimental data. Finally, a model-based controller is designed to track position references generated from the network through linear matrix inequalities. The biomimetic control algorithm is tested in simulation and a physical setup to show the effectiveness of the novel control method.Note to Practitioners—This work addresses the challenge of real-time control of lower-limb exoskeletons. Our approach to address the trajectory generation problem involves emulating the movements of a healthy limb. This is achieved through a robust sensor fusion algorithm to integrate data from two multimodal sensors, namely, FMG and IMU sensors, enabling a reliable estimation of the hip and knee’s angular positions. Signals are processed and neural networks are trained with exoskeleton encoder measurements as targets. Physical tests show both the accuracy and robustness of the control method. Potential applications of the new method include real-time gait analysis, control of upper limb exoskeletons, and study of the induction of neural plasticity.

Overview

Integrity signals

Registry

Crossref · 10.1109/tase.2024.3421318

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 29 references

Research works printed but not linked: 3

  1. Haykin, 1998, Neural Networks: A Comprehensive Foundation
  2. Heaton, 2008, Introduction to Neural Networks With Java
  3. 10.1007/978-1-4612-1768-8_11 · DOI

Cited by

Sorted by citations

See all 21

Metadata

Authors
Arceo, J. C., Yu, L., & Bai, S.
Affiliations
Aalborg University (DK)
Venue
IEEE Transactions on Automation Science and Engineering
Published
2025
Volume
22
Pages
5425-5435
ISSN
  • 1545-5955 (ISSN-L)
  • 1558-3783
OpenAlex
W4400314290
Cited by
19
References
29
Citations by year
2026: 8 · 2025: 10
FWCI
2.09
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Automation Science and Engineering (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
Funders
ALEXO project through Frode V
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Computer Science › Computer Graphics and Computer-Aided Design › Human Motion and Animation
Keywords
lower limb exoskeleton, sensor fusion, force myography, inertial measurement unit, multimodal sensors, biomimetic control, linear matrix inequalities, model-based control, trajectory tracking, gait analysis, neuroplasticity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review