Compensation of tissue absorption in emission tomography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents a technique for overcoming the problem of tissue absorption in emission tomography. Given a set of equispaced projections in the interval (0, 2π), it is possible to derive an exact formula for recovering the spectrum of the image. The formula is obtained by solving a linear partial-differential equation that links the derivatives of the spectrum with respect to absorption and spatial frequencies. Examples of the application of the technique to synthetic and real data are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Strip Integration in Radio Astronomy
Bracewell, R. (1956) · Australian Journal of Physics · doi:10.1071/ph560198 · Cited by 682
Digital reconstruction of multidimensional signals from their projections
Mersereau, R. M., & Oppenheim, A. V. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9625 · Cited by 435 · cited 1×
“Of course, in practical cases one has a finite set of projections and linear interpolation is required [ 5 ] . When using the Fourier method, the complex function F(R, q5) is known on a polar raster.”
Method
Cited by
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Dopamine D2 Receptor Imaging with SPECT: Studies in Different Neuropsychiatric Disorders
Brücke, T., Podreka, I., Angelberger, P., Wenger, S., Topitz, A., Küfferle, B., Müller, C., & Deecke, L. (1991) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1991.53 · Cited by 206
Overview of methods for image reconstruction from projections in emission computed tomography
Lewitt, R. M., & Matej, S. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817882 · Cited by 200
“Books directed primarily to mathematicians include [186], [187], and there is an extensive literature in the related branch of mathematics (integral geometry).”
BackgroundAn attenuated projector-backprojector for iterative SPECT reconstruction
Gullberg, G. T., Huesman, R. H., Malko, J. A., Pelc, N. J., & Budinger, T. F. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/8/004 · Cited by 173
Pretorius, P. H., King, M. A., Pan, T.-S., Vries, D. J. D., Glick, S. J., & Byrne, C. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/2/014 · Cited by 72
Metadata
- Authors
- Bellini, S., Piacentini, M., Cafforio, C., & Rocca, F.
- Venue
- IEEE Transactions on Acoustics, Speech, and Signal Processing
- Published
- 1979-06
- Volume
- 27
- Issue
- 3
- Pages
- 213-218
- ISSN
- 0096-3518 (ISSN-L)
- OpenAlex
- W2139589416
- Cited by
- 231
- References
- 3
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.