The reconstruction of a multidimensional sequence from the phase or magnitude of its Fourier transform
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper addresses two fundamental issues involved in the reconstruction of a multidimensional sequence from either the phase or magnitude of its Fourier transform. The first issue relates to the uniqueness of a multidimensional sequence in terms of its phase or magnitude. Although phase or magnitude information alone is not sufficient, in general, to uniquely specify a sequence, a large class of sequences are shown to be recoverable from their phase or magnitude. The second issue which is addressed in this paper concerns the actual reconstruction of a multidimensional sequence from its phase or magnitude. For those sequences which are uniquely specified by their phase, several practical algorithms are described which may be used to reconstruct a sequence from its phase. Several examples of phase-only reconstruction are also presented. Unfortunately, however, even for those sequences which are uniquely defined by their magnitude, it appears that a practical algorithm is yet to be developed for reconstructing a sequence from only its magnitude. Nevertheless, an iterative procedure which has been proposed is briefly discussed and evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iterative Solution of Nonlinear Equations in Several Variables
I., E., Ortega, J. M., & Rheinboldt, W. C. (1971) · Mathematics of Computation · doi:10.2307/2004942 · Cited by 4,408
Mark, J. W. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9993 · Cited by 1,565
Sondhi, M. (1978) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1978.1163057 · Cited by 539
Blind deconvolution through digital signal processing
Stockham, T. G., Cannon, T. M., & Ingebretsen, R. B. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9800 · Cited by 341
Introduction to Higher Algebra
(1964) · Elsevier eBooks · doi:10.1016/c2013-0-10019-0 · Cited by 333
Convergence of iterative nonexpansive signal reconstruction algorithms
Tom, V. T., Quatieri, T. F., Hayes, M. H., III, & McClellan, J. H. (1981) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1981.1163681 · Cited by 107
Cited by
Understanding and evaluating blind deconvolution algorithms
Levin, A., Weiss, Y., Durand, F., & Freeman, W. T. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206815 · Cited by 1,208
“[8] states that for most of kernels, a finite support constraint uniquely defines the signal phase, up to (1) shift and (2) flipping (mirroring).”
BackgroundPhase Retrieval with Application to Optical Imaging: A contemporary overview
Shechtman, Y., Eldar, Y. C., Cohen, O., Chapman, H. N., Miao, J., & Segev, M. (2015) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2352673 · Cited by 1,131
Phase Retrieval via Wirtinger Flow: Theory and Algorithms
Candès, E. J., Li, X., & Soltanolkotabi, M. (2015) · IEEE Transactions on Information Theory · doi:10.1109/tit.2015.2399924 · Cited by 1,049
Image Restoration by the Method of Convex Projections: Part 1ߞTheory
Youla, D. C., & Webb, H. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307555 · Cited by 1,021
Phase retrieval in crystallography and optics
Millane, R. P. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.000394 · Cited by 720
Three-dimensional mapping of a deformation field inside a nanocrystal
Pfeifer, M. A., Williams, G. J., Vartanyants, I. A., Harder, R., & Robinson, I. K. (2006) · Nature · doi:10.1038/nature04867 · Cited by 697
Multiresolution spectrotemporal analysis of complex sounds
Chi, T., Ru, P., & Shamma, S. A. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1945807 · Cited by 673
Soft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
Phase Retrieval via Matrix Completion
Candès, E. J., Eldar, Y. C., Strohmer, T., & Voroninski, V. (2013) · SIAM Journal on Imaging Sciences · doi:10.1137/110848074 · Cited by 565
Phase Retrieval Using Alternating Minimization
Netrapalli, P., Jain, P., & Sanghavi, S. (2015) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2015.2448516 · Cited by 535
The Convex Feasibility Problem in Image Recovery
Combettes, P. L. (1996) · Advances in Imaging and Electron Physics · doi:10.1016/s1076-5670(08)70157-5 · Cited by 490
Phase Retrieval via Matrix Completion
Candès, E. J., Eldar, Y. C., Strohmer, T., & Voroninski, V. (2015) · SIAM Review · doi:10.1137/151005099 · Cited by 481
Understanding Blind Deconvolution Algorithms
Levin, A., Weiss, Y., Durand, F., & Freeman, W. T. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.148 · Cited by 425
Consensus-ADMM for General Quadratically Constrained Quadratic Programming
Huang, K., & Sidiropoulos, N. D. (2016) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2016.2593681 · Cited by 242
“ch measurements can be directly obtained using optics, and have the nice property that the model is identifiable (up to a global phase ambiguity and conjugate inversion) for real signals almost surely [11]. Despite this uniqueness property, the recovery problem per se is known to be very hard from a computational point…”
BackgroundElectron and X‐Ray Methods of Ultrafast Structural Dynamics: Advances and Applications
Chergui, M., & Zewail, A. H. (2009) · ChemPhysChem · doi:10.1002/cphc.200800667 · Cited by 232
A transformation method for the reconstruction of functions from nonuniformly spaced samples
Clark, J., Palmer, M., & Lawrence, P. (1985) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1985.1164714 · Cited by 225
Coherent X-Ray Diffraction Imaging
Miao, J., Sandberg, R. L., & Song, C. (2012) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2011.2157306 · Cited by 172
“Subsequently, Bruck and Sodin [72], Hayes [73], and Bates [74] concluded that when the diffraction pattern of a multidimensional (≥2) object is sampled at least twice finer than the Nyquist frequency in each dimension, the phases are uniquely encoded inside the diffraction pattern, except for some special 1077-260X/$2…”
BackgroundInfluentialPattern recognition by labeled graph matching
von der Malsburg, C. (1988) · Neural Networks · doi:10.1016/0893-6080(88)90016-0 · Cited by 162
Metadata
- Authors
- Hayes, M.
- Venue
- IEEE Transactions on Acoustics, Speech, and Signal Processing
- Published
- 1982-04
- Volume
- 30
- Issue
- 2
- Pages
- 140-154
- ISSN
- 0096-3518 (ISSN-L)
- OpenAlex
- W2136328862
- Cited by
- 431
- References
- 6
- FWCI
- 18.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.