A Wireless Biomedical Signal Interface System-on-Chip for Body Sensor Networks
Abstract
Recent years have seen the rapid development of biosensor technology, system-on-chip design, wireless technology. and ubiquitous computing. When assembled into an autonomous body sensor network (BSN), the technologies become powerful tools in well-being monitoring, medical diagnostics, and personal connectivity. In this paper, we describe the first demonstration of a fully customized mixed-signal silicon chip that has most of the attributes required for use in a wearable or implantable BSN. Our intellectual-property blocks include low-power analog sensor interface for temperature and pH, a data multiplexing and conversion module, a digital platform based around an 8-b microcontroller, data encoding for spread-spectrum wireless transmission, and a RF section requiring very few off-chip components. The chip has been fully evaluated and tested by connection to external sensors, and it satisfied typical system requirements.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Wang et al. SOC includes a generic sensor interface, ADC, microcontroller, a data encoder and a frequency-shift keying RF transmitter.
“Their SOC includes generic sensor interface, ADC, microcontroller, a data encoder and a frequency-shift keying RF transmitter.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [34]
Wang et al. developed a system-on-chip (SOC), which integrates a pH and temperature sensor, for remote monitoring applications.
“Wang et al. [34] developed a system-on-chip (SOC), which integrates a pH and temperature sensor, for remote monitoring applications.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [34]
The citation lists haven’t been fetched yet
References 24 · Cited by 84
- Authors
- Wang, L., Yang, G.-Z., Huang, J., Zhang, J., Yu, L., Nie, Z., & Cumming, D. R. S.
- Affiliations
- Chinese Academy of Sciences (CN)
- Imperial College London (GB)
- University of Glasgow (GB)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2010-04
- Volume
- 4
- Issue
- 2
- Pages
- 112-117
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2125101482
- Cited by
- 84
- References
- 24
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 4 · 2023: 5 · 2022: 5 · 2021: 10 · 2020: 6 · 2019: 1 · 2018: 4 · 2017: 5 · 2016: 2 · 2015: 5 · 2014: 12 · 2013: 6 · 2012: 6
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/C547586/1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- wireless body area networks, system-on-chip, mixed-signal circuits, wearable sensors, implantable sensors, temperature sensing, pH sensing, data multiplexing, microcontroller, RF front-end
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review