An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We report the development of an Electronic Patch for wearable health monitoring. The Electronic Patch is a new health monitoring system incorporating biomedical sensors, microelectronics, radio frequency (RF) communication, and a battery embedded in a 3-dimensional hydrocolloid polymer. In this paper the Electronic Patch is demonstrated with a new optical biomedical sensor for reflectance pulse oximetry so that the Electronic Patch in this case can measure the pulse and the oxygen saturation. The reflectance pulse oximetry solution is based on a recently developed annular backside silicon photodiode to enable low power consumption by the light emitting components. The Electronic Patch has a disposable part of soft adhesive hydrocolloid polymer and a reusable part of hard polylaurinlactam. The disposable part contains the battery. The reusable part contains the reflectance pulse oximetry sensor and microelectronics. The reusable part is 'clicked' into the disposable part when the patch is prepared for use. The patch has a size of 88 mm by 60 mm and a thickness of 5 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Heart Rate Assessment Immediately after Birth
Phillipos, E., Solevåg, A. L., Pichler, G., Aziz, K., van Os, S., O''Reilly, M., Cheung, P.-Y., & Schmölzer, G. M. (2016) · Neonatology · doi:10.1159/000441940 · Cited by 531
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
“presented a patch SpO2 monitor that used an annular backside silicon photodiode can decrease the power consumption of the oximeter sensor [32].”
MethodAdvances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
Metadata
- Authors
- Haahr, R. G., Duun, S. B., Toft, M. H., Belhage, B., Larsen, J., Birkelund, K., & Thomsen, E. V.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2012-02
- Volume
- 6
- Issue
- 1
- Pages
- 45-53
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2056016955
- Cited by
- 100
- References
- 2
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry. https://app.cochat.ai/papers/10.1109/tbcas.2011.2164247
- The paper
- Haahr, R. G., Duun, S. B., Toft, M. H., Belhage, B., Larsen, J., Birkelund, K., & Thomsen, E. V. (2012). An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2011.2164247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.