The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Heart Rate Assessment Immediately after Birth
Abstract
Background: Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. Objective: The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. Methods: PubMed, EMBASE and Google Scholar were systematically searched using the following terms: ‘infant', ‘heart rate', ‘monitoring', ‘delivery room', ‘resuscitation', ‘stethoscope', ‘auscultation', ‘palpation', ‘pulse oximetry', ‘electrocardiogram', ‘Doppler ultrasound', ‘photoplethysmography' and ‘wearable sensors'. Results: Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Conclusion: Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peberdy, M. A., Callaway, C. W., Neumar, R. W., Geocadin, R. G., Zimmerman, J. L., Donnino, M., Gabrielli, A., Silvers, S. M., Zaritsky, A. L., Merchant, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971002 · Cited by 2,522
Callaway, C. W., Soar, J., Aibiki, M., Böttiger, B. W., Brooks, S. C., Deakin, C. D., Donnino, M. W., Drajer, S., Kloeck, W., Morley, P. T., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000273 · Cited by 1,390
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
A proposal for a new method of evaluation of the newborn infant.
APGAR, V. (1953) · PubMed · Cited by 787
Part 11: Neonatal resuscitation
Wyllie, J., Perlman, J. M., Kattwinkel, J., Atkins, D. L., Chameides, L., Goldsmith, J. P., Guinsburg, R., Hazinski, M. F., Morley, C., Richmond, S., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.029 · Cited by 601
Defining the Reference Range for Oxygen Saturation for Infants After Birth
Dawson, J. A., Kamlin, C. O. F., Vento, M., Wong, C., Cole, T. J., Donath, S. M., Davis, P. G., & Morley, C. J. (2010) · Pediatrics · doi:10.1542/peds.2009-1510 · Cited by 553
Kattwinkel, J., Perlman, J. M., Aziz, K., Colby, C., Fairchild, K., Gallagher, J., Hazinski, M. F., Halamek, L. P., Kumar, P., Little, G., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971119 · Cited by 498
Self-citationA Proposal for a New Method of Evaluation of the Newborn Infant
Apgar, V. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31829bdc5c · Cited by 236
Accuracy of clinical assessment of infant heart rate in the delivery room
Kamlin, C. O. F., O’Donnell, C. P. F., Everest, N. J., Davis, P. G., & Morley, C. J. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2006.04.015 · Cited by 216
Changes in heart rate in the first minutes after birth
Dawson, J. A., Kamlin, C., Wong, C., Pas, A. B. T., Vento, M., Cole, T. J., Donath, S. M., Hooper, S. B., Davis, P. G., & Morley, C. J. (2010) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/adc.2009.169102 · Cited by 190
Cited by
European Consensus Guidelines on the Management of Respiratory Distress Syndrome – 2019 Update
Sweet, D. G., Carnielli, V., Greisen, G., Hallman, M., Ozek, E., te Pas, A., Plavka, R., Roehr, C. C., Saugstad, O. D., Simeoni, U., et al. (2019) · Neonatology · doi:10.1159/000499361 · Cited by 1,613
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
The Spectrum of Epidemiology Underlying Sudden Cardiac Death
Hayashi, M., Shimizu, W., & Albert, C. M. (2015) · Circulation Research · doi:10.1161/circresaha.116.304521 · Cited by 719
An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare
Yang, Z., Zhou, Q., Lei, L., Zheng, K., & Xiang, W. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0644-9 · Cited by 490
Berg, M. D., Schexnayder, S. M., Chameides, L., Terry, M., Donoghue, A., Hickey, R. W., Berg, R. A., Sutton, R. M., & Hazinski, M. F. (2010) · Pediatrics · doi:10.1542/peds.2010-2972c · Cited by 398
Metadata
- Authors
- Phillipos, E., Solevåg, A. L., Pichler, G., Aziz, K., van Os, S., O''Reilly, M., Cheung, P.-Y., & Schmölzer, G. M.
- Venue
- Neonatology
- Publisher
- S. Karger AG
- Published
- 2015-12-19
- Volume
- 109
- Issue
- 2
- Pages
- 130-138
- ISSN
- 1661-7800 (ISSN-L)
- 1661-7819
- OpenAlex
- W2199185488
- Cited by
- 531
- References
- 24
- FWCI
- 28.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart Rate Assessment Immediately after Birth. https://app.cochat.ai/papers/10.1159/000441940
- The paper
- Phillipos, E., Solevåg, A. L., Pichler, G., Aziz, K., van Os, S., O''Reilly, M., Cheung, P.-Y., & Schmölzer, G. M. (2016). Heart Rate Assessment Immediately after Birth. Neonatology. https://doi.org/10.1159/000441940
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.