A 128-Channel Extreme Learning Machine-Based Neural Decoder for Brain Machine Interfaces
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Currently, state-of-the-art motor intention decoding algorithms in brain-machine interfaces are mostly implemented on a PC and consume significant amount of power. A machine learning coprocessor in 0.35- μm CMOS for the motor intention decoding in the brain-machine interfaces is presented in this paper. Using Extreme Learning Machine algorithm and low-power analog processing, it achieves an energy efficiency of 3.45 pJ/MAC at a classification rate of 50 Hz. The learning in second stage and corresponding digitally stored coefficients are used to increase robustness of the core analog processor. The chip is verified with neural data recorded in monkey finger movements experiment, achieving a decoding accuracy of 99.3% for movement type. The same coprocessor is also used to decode time of movement from asynchronous neural spikes. With time-delayed feature dimension enhancement, the classification accuracy can be increased by 5% with limited number of input channels. Further, a sparsity promoting training scheme enables reduction of number of programmable weights by ≈ 2X.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efron, B., Hastie, T., Johnstone, I., & Tibshirani, R. (2004) · The Annals of Statistics · doi:10.1214/009053604000000067 · Cited by 9,357
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
Low-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91
A Digitally Assisted, Signal Folding Neural Recording Amplifier
Chen, Y., Basu, A., Liu, L., Zou, X., Rajkumar, R., Dawe, G. S., & Je, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2288680 · Cited by 43 · cited 1×
“Significant effort has been dedicate d to develop energy efficient neural recording channel in rece nt years for long-term operation of the implanted devices [1] [2] [3] [4].”
BackgroundSelf-citation
Cited by
Maimaitijiang, M., Ghulam, A., Sidike, P., Hartling, S., Maimaitiyiming, M., Peterson, K., Shavers, E., Fishman, J., Peterson, J., Kadam, S., et al. (2017) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2017.10.011 · Cited by 387
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
A survey on the development status and application prospects of knowledge graph in smart grids
Wang, J., Wang, X., Ma, C., & Kou, L. (2021) · IET Generation, Transmission & Distribution · doi:10.1049/gtd2.12040 · Cited by 111
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Metadata
- Authors
- Chen, Y., Yao, E., & Basu, A.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2016-06
- Volume
- 10
- Issue
- 3
- Pages
- 679-692
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2185491959
- Cited by
- 117
- References
- 7
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 128-Channel Extreme Learning Machine-Based Neural Decoder for Brain Machine Interfaces. https://app.cochat.ai/papers/10.1109/tbcas.2015.2483618
- The paper
- Chen, Y., Yao, E., & Basu, A. (2016). A 128-Channel Extreme Learning Machine-Based Neural Decoder for Brain Machine Interfaces. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2015.2483618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.