CoChat

Closed-Loop Neurostimulators: A Survey and A Seizure-Predicting Design Example for Intractable Epilepsy Treatment

Kassiri, Hossein, Tonekaboni, Sana, Salam, M. Tariqus, Soltani, Nima, Abdelhalim, Karim, Velazquez, Jose Luis Perez, Genov, Roman · 2017 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 117

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

First, existing commercially available open-loop and closed-loop implantable neurostimulators are reviewed and compared in terms of their targeted application, physical size, system-level features, and performance as a medical device. Next, signal processing algorithms as the primary strength point of the closed-loop neurostimulators are reviewed, and various design and implementation requirements and trade-offs are discussed in details along with quantitative examples. The review results in a set of guidelines for algorithm selection and evaluation. Second, the implementation of an inductively-powered seizure-predicting microsystem for monitoring and treatment of intractable epilepsy is presented. The miniaturized system is comprised of two miniboards and a power receiver coil. The first board hosts a 24-channel neurostimulator system on chip fabricated in a [Formula: see text] CMOS technology and performs neural recording, on-chip digital signal processing, and electrical stimulation. The second board communicates recorded brain signals as well as signal processing results wirelessly. The multilayer flexible coil receives inductively-transmitted power. The system is sized at 2 × 2 × 0.7 [Formula: see text] and weighs 6 g. The approach is validated in the control of chronic seizures in vivo in freely moving rats.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2017.2694638

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 117

Metadata

Authors
Kassiri, H., Tonekaboni, S., Salam, M. T., Soltani, N., Abdelhalim, K., Velazquez, J. L. P., & Genov, R.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2017-10
Volume
11
Issue
5
Pages
1026-1040
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2736148182
Cited by
117
References
4
FWCI
5.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Closed-Loop Neurostimulators: A Survey and A Seizure-Predicting Design Example for Intractable Epilepsy Treatment. https://app.cochat.ai/papers/10.1109/tbcas.2017.2694638
The paper
Kassiri, H., Tonekaboni, S., Salam, M. T., Soltani, N., Abdelhalim, K., Velazquez, J. L. P., & Genov, R. (2017). Closed-Loop Neurostimulators: A Survey and A Seizure-Predicting Design Example for Intractable Epilepsy Treatment. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2017.2694638

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.