The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Discrimination of EMG Signals Using a Neuromorphic Implementation of a Spiking Neural Network
Open accessAbstract
An accurate description of muscular activity plays an important role in the clinical diagnosis and rehabilitation research. The electromyography (EMG) is the most used technique to make accurate descriptions of muscular activity. The EMG is associated with the electrical changes generated by the activity of the motor neurons. Typically, to decode the muscular activation during different movements, a large number of individual motor neurons are monitored simultaneously, producing large amounts of data to be transferred and processed by the computing devices. In this paper, we follow an alternative approach that can be deployed locally on the sensor side. We propose a neuromorphic implementation of a spiking neural network (SNN) to extract spatio-temporal information of EMG signals locally and classify hand gestures with very low power consumption. We present experimental results on the input data stream using a mixed-signal analog/digital neuromorphic processor. We performed a thorough investigation on the performance of the SNN implemented on the chip, by: first, calculating PCA on the activity of the silicon neurons at the input and the hidden layers to show how the network helps in separating the samples of different classes; second, performing classification of the data using state-of-the-art SVM and logistic regression methods and a hardware-friendly spike-based read-out. The traditional algorithm achieved a classification rate of [Formula: see text] and [Formula: see text], respectively, and the spiking learning method achieved [Formula: see text]. The power consumption of the SNN is [Formula: see text], showing the potential of this approach for ultra-low power processing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WIDROW, B., & HOFF, M. E. (1960) · doi:10.21236/ad0241531 · Cited by 4,009
Cited by
2022 roadmap on neuromorphic computing and engineering
Christensen, D. V., Dittmann, R., Linares-Barranco, B., Sebastian, A., Le Gallo, M., Redaelli, A., Slesazeck, S., Mikolajick, T., Spiga, S., Menzel, S., et al. (2022) · Neuromorphic Computing and Engineering · doi:10.1088/2634-4386/ac4a83
Self-citation
Metadata
- Authors
- Donati, E., Payvand, M., Risi, N., Krause, R., & Indiveri, G.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2019-10
- Volume
- 13
- Issue
- 5
- Pages
- 795-803
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2955596007
- Cited by
- 189
- References
- 1
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrimination of EMG Signals Using a Neuromorphic Implementation of a Spiking Neural Network. https://app.cochat.ai/papers/10.1109/tbcas.2019.2925454
- The paper
- Donati, E., Payvand, M., Risi, N., Krause, R., & Indiveri, G. (2019). Discrimination of EMG Signals Using a Neuromorphic Implementation of a Spiking Neural Network. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2019.2925454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.