Cited by 56Analog and Mixed-Signal Circuit DesignEEG and Brain-Computer InterfacesNeuroscience and Neural Engineering

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

A 9.2-g fully-flexible wireless ambulatory EEG monitoring and diagnostics headband with analog motion artifact detection and compensation.

Dabbaghian, Alireza, Yousefi, Tayebeh, Fatmi, Syyeda Zainab, Shafia, Pooria, Kassiri, Hossein·2019·IEEE Transactions on Biomedical Circuits and Systems

Abstract

An 8-channel wearable wireless device for ambulatory surface EEG monitoring and analysis is presented. The entire multi-channel recording, quantization, and motion artifact removal circuitries are implemented on a 4-layer polyimide flexible substrate. The recording electrodes and active shielding are also integrated on the same substrate, yielding the smallest form factor compared to the state of the art. Thanks to the dry non-contact electrodes, the system is quickly mountable with minimal assistance required, making it an ideal ambulatory front- and temporal-lobe EEG monitoring device. The flexible main board is connected to a rechargeable battery on one end and to a 13 × 17 mm2rigid board on the other end. The mini rigid board hosts a low-power programmable FPGA and a BLE 5.0 transceiver, which add diagnostic capability and wireless connectivity features to the device, respectively. Design considerations for a wearable EEG monitoring and diagnostic device are discussed in details. The theory of the novel fully-analog method for motion artifact detection and removal is described and the detailed circuit implementation is presented. The device performance in terms of voltage gain (260 V/V), bandwidth (DC-300 Hz), motion artifact removal, and wireless communication throughput (up to 1 Mbps) is experimentally validated. The entire wearable solution with the battery weighs 9.2 grams.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbcas.2019.2936327

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 25 references

Research works printed but not linked: 2

  1. 10.1001/archinte.1986.00360220067013 · DOI
  2. wolfe, 2002, Coma and depressed level of consciousness, Rosen's Emergency Medicine - Concepts and Clinical Practice, 137

Cited by

Sorted by citations

Metadata

Authors
Dabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H.
Affiliations
York University (CA)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2019-12
Volume
13
Issue
6
Pages
1141-1151
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2969463944
Cited by
56
References
25
Citations by year
2026: 3 · 2025: 9 · 2024: 9 · 2023: 15 · 2022: 7 · 2021: 6 · 2020: 7
FWCI
1.76
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Natural Sciences and Engineering Research Council of Canada
  • CMC Microsystems
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
ambulatory EEG, motion artifact detection, motion artifact reduction, analog circuit design, polyimide substrate, active shielding, low-power FPGA, low power design
MeSH terms
Wearable Electronic Devices, Amplifiers, Electronic, Electroencephalography, Equipment Design, Humans, Signal Processing, Computer-Assisted, Artifacts, Monitoring, Ambulatory, Diagnostic Equipment, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review