The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A 9.2-g fully-flexible wireless ambulatory EEG monitoring and diagnostics headband with analog motion artifact detection and compensation.
Abstract
An 8-channel wearable wireless device for ambulatory surface EEG monitoring and analysis is presented. The entire multi-channel recording, quantization, and motion artifact removal circuitries are implemented on a 4-layer polyimide flexible substrate. The recording electrodes and active shielding are also integrated on the same substrate, yielding the smallest form factor compared to the state of the art. Thanks to the dry non-contact electrodes, the system is quickly mountable with minimal assistance required, making it an ideal ambulatory front- and temporal-lobe EEG monitoring device. The flexible main board is connected to a rechargeable battery on one end and to a 13 × 17 mm2rigid board on the other end. The mini rigid board hosts a low-power programmable FPGA and a BLE 5.0 transceiver, which add diagnostic capability and wireless connectivity features to the device, respectively. Design considerations for a wearable EEG monitoring and diagnostic device are discussed in details. The theory of the novel fully-analog method for motion artifact detection and removal is described and the detailed circuit implementation is presented. The device performance in terms of voltage gain (260 V/V), bandwidth (DC-300 Hz), motion artifact removal, and wireless communication throughput (up to 1 Mbps) is experimentally validated. The entire wearable solution with the battery weighs 9.2 grams.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The artifact is typically hundreds of millivolts in amplitude, and 10 to 100 times higher than the amplitude of the recorded neural signals (Dabbaghian et al., 2019; Lee and Je, 2020).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Dabbaghian et al., 2019
Citations
Cites
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,069
Application of machine learning to epileptic seizure onset detection and treatment
Shoeb, A. H. (2009) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 855
Learning Robust Features using Deep Learning for Automatic Seizure DetectionPreprint
Thodoroff, P., Pineau, J., & Lim, A. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1608.00220 · Cited by 229
A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazıcıoğlu, R. F., Grundlehner, B., Harpe, P. J. A., Makinwa, K. A. A., & Hoof, C. A. V. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 224
Altered mental status: Evaluation and etiology in the ED
Kanich, W., Brady, W. J., Huff, J. S., Perron, A. D., Holstege, C. P., Lindbeck, G., & Carter, C. T. (2002) · The American Journal of Emergency Medicine · doi:10.1053/ajem.2002.35464 · Cited by 215
Dementia Among Medical Inpatients
Erkinjuntti, T. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.146.10.1923 · Cited by 200
Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Velázquez, J. L. P., Carlen, P. L., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160
Self-citationVespa, P. M. (2005) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000154919.54202.e0 · Cited by 148
Altaf, M. A. B., & Yoo, J. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2386891 · Cited by 134
Learning Robust Features using Deep Learning for Automatic Seizure Detection
Thodoroff, P., Pineau, J., & Lim, A. (2016) · Cited by 129
A Wearable 8-Channel Active-Electrode EEG/ETI Acquisition System for Body Area Networks
Xu, J., Mitra, S., Matsumoto, A., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2325557 · Cited by 126
Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks
Yu, M., Deiss, S. R., & Cauwenberghs, G. (2009) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.52 · Cited by 126
A 15-Channel Digital Active Electrode System for Multi-Parameter Biopotential Measurement
Xu, J., Busze, B., Hoof, C. A. V., Makinwa, K. A. A., & Yazıcıoğlu, R. F. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2422798 · Cited by 121
Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2528999 · Cited by 117
Self-citationKassiri, H., Tonekaboni, S., Salam, M. T., Soltani, N., Abdelhalim, K., Velázquez, J. L. P., & Genov, R. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2694638 · Cited by 114
Self-citationGuermandi, M., Cardu, R., Scarselli, E. F., & Guerrieri, R. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2311836 · Cited by 85
Problems in equivalent circuit modelling of the electrical properties of biological tissues
McAdams, E. T., & JOSSINET, J. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(96)05069-6 · Cited by 67
Kassiri, H., Pazhouhandeh, M. R., Soltani, N., Salam, M. T., Carlen, P. L., Perez-Velazquez, J. L., & Genov, R. (2017) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2017.7870456 · Cited by 51
Self-citationDifferential Diagnosis of Dementia, Delirium and Depression
Johnson, J. C., Sims, R. V., & Gottlieb, G. L. (1994) · Drugs & Aging · doi:10.2165/00002512-199405060-00005 · Cited by 45
Salam, M. T., Kassiri, H., Genov, R., & Velázquez, J. L. P. (2015) · Epilepsia · doi:10.1111/epi.13064 · Cited by 40
Self-citationElectronic Sleep Stage Classifiers: A Survey and VLSI Design Methodology
Kassiri, H., Chemparathy, A., Salam, M. T., Boyce, R., Adamantidis, A., & Genov, R. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2540438 · Cited by 36
Self-citationTradeoffs between wireless communication and computation in closed-loop implantable devices
Salam, M. T., Kassiri, H., Soltani, N., He, H., Velázquez, J. L. P., & Genov, R. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7538928 · Cited by 21
Self-citationKassiri, H., Pazhouhandeh, M. R., Soltani, N., Salam, M. T., Peter, C., Luiz, P. V. J., & Roman, G. (2017) · IEEE Conference Proceedings · Cited by 18
Self-citationA Resource-Optimized VLSI Architecture for Patient-Specific Seizure Detection using Frontal-Lobe EEG
Zhan, T., Guraya, S., & Kassiri, H. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702211 · Cited by 18
Self-citationDabbaghian, A., Yousefi, T., Shafia, P., et al. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702403 · Cited by 8
Self-citation
Research works printed but not linked: 2
- 10.1001/archinte.1986.00360220067013 · DOI
- wolfe, 2002, Coma and depressed level of consciousness, Rosen's Emergency Medicine - Concepts and Clinical Practice, 137
Cited by
Sorted by citations
Advances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
Metadata
- Authors
- Dabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H.
- Affiliations
- York University (CA)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2019-12
- Volume
- 13
- Issue
- 6
- Pages
- 1141-1151
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2969463944
- Cited by
- 56
- References
- 25
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 9 · 2023: 15 · 2022: 7 · 2021: 6 · 2020: 7
- FWCI
- 1.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- CMC Microsystems
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- ambulatory EEG, motion artifact detection, motion artifact reduction, analog circuit design, polyimide substrate, active shielding, low-power FPGA, low power design
- MeSH terms
- Wearable Electronic Devices, Amplifiers, Electronic, Electroencephalography, Equipment Design, Humans, Signal Processing, Computer-Assisted, Artifacts, Monitoring, Ambulatory, Diagnostic Equipment, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review