Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 313

The DOI matches its Crossref record.

An Electrically Calibrated Plethysmograph for Direct Measurement of Limb Blood Flow

Hokanson, D. Eugene, Sumner, David S., Strandness, D. Eugene·1975·IEEE Transactions on Biomedical Engineering

Abstract

This paper describes an electrically calibrated plethysmograph which may be used with all lengths of mercury-in-rubber strain gauges. Due to the very low resistance of these strain gauges, electrical calibration of previously available plethysmographs has suffered from errors caused by lead-wire resistance. The present instrument eliminates lead-wire errors by a design which effectively places the strain gauge at the corners of the measurement bridge. Linearity of the output for large changes in gauge resistance has been insured by the incorporation of a constant-current bridge supply.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1975.324535

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 313

Metadata

Authors
Hokanson, D. E., Sumner, D. S., & Strandness, D. E.
Venue
IEEE Transactions on Biomedical Engineering
Published
1975-01
Volume
BME-22
Issue
1
Pages
25-29
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1982072215
Cited by
313
References
0
FWCI
1.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Electrically Calibrated Plethysmograph for Direct Measurement of Limb Blood Flow. https://app.cochat.ai/papers/10.1109/tbme.1975.324535
The paper
Hokanson, D. E., Sumner, D. S., & Strandness, D. E. (1975). An Electrically Calibrated Plethysmograph for Direct Measurement of Limb Blood Flow. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1975.324535

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.