Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

Simple Equipment Used in Clinical Practice for Evaluation of Locomotion

Pedotti, Antonio·1977·IEEE Transactions on Biomedical Engineering

Abstract

A new simple procedure for analyzing and evaluating human gait that can be easily performed in clinical practice is presented. Signals proportional to forces produced by a subject walking along a walkway are registered by a common force plate and processed by a specially made hybrid computer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1977.326186

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Pedotti, A.
Venue
IEEE Transactions on Biomedical Engineering
Published
1977-09
Volume
BME-24
Issue
5
Pages
456-461
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1982392827
Cited by
176
References
0
FWCI
1.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simple Equipment Used in Clinical Practice for Evaluation of Locomotion. https://app.cochat.ai/papers/10.1109/tbme.1977.326186
The paper
Pedotti, A. (1977). Simple Equipment Used in Clinical Practice for Evaluation of Locomotion. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1977.326186

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.