Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing

Ferrigno, Giancarlo, Pedotti, Antonio·1985·IEEE Transactions on Biomedical Engineering

Abstract

The system illustrated in this paper has been designed and developed particularly for automatic and reliable analysis of body movement in various conditions and environments. It is based on real-time processing of the TV images to recognize multiple passive markers and compute their coordinates. This performance is achieved by using a special algorithm allowing the recognition of markers only if their shape matches a predetermined "mask." The main feature of the system is a two-level processing architecture, the first of which includes a dedicated peripheral fast processor for shape recognition (FPSR), designed and implemented by using fast VLSI chips. The second level consists of a general purpose computer and provides the overall system with high flexibility. The main characteristics are: no restriction on the number of markers, resolution of one part in 2500, and a 50 Hz sampling rate independent of the number of markers detected. The prototype has been fully developed, and preliminary results obtained from the analysis of several movements are illustrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1985.325627

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 576

Metadata

Authors
Ferrigno, G., & Pedotti, A.
Venue
IEEE Transactions on Biomedical Engineering
Published
1985-11
Volume
BME-32
Issue
11
Pages
943-950
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2009042050
Cited by
576
References
0
FWCI
7.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing. https://app.cochat.ai/papers/10.1109/tbme.1985.325627
The paper
Ferrigno, G., & Pedotti, A. (1985). Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1985.325627

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.