Quantitative Evaluation of Long-Term Parkinson Tremor
The DOI matches its Crossref record.
Abstract
Because of wide temporal fluctuations in the severity of Parkinson tremor, long-term observation is required to objectively assess the effects of therapy. This study was conducted to design a system for long-term recording of tremor in the digits or wrist, to examine the stochastic properties of tremor, and to develop a means for temporally compressing the data for rapid clinical interpretation. Forty patients were studied. A telemetry system was used for data acquistion to allow the patients freedom of movement during the recording session. Recording length ranged from ½to 6 h with a mean of 2 h. The data were found to be self-stationary in the wide sense over 1-min epochs. The statistical properties varied with time in individual subjects and there was little uniformity among different subjects. Cross-correlation and cross-spectral density analyses indicated that tremor at corresponding sites in contralateral limbs is relatively independent. Graphs of percent on time, mean frequency, and mean amplitude for contiguous 3-5-min epochs were found most suitable for clinical purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 18
- randall, 1964, power spectral analysis of finger acceleration tremor, J Appl Physiol, 19, 357, 10.1152/jappl.1964.19.2.357 · DOI
- 10.1136/jnnp.20.4.302 · doi:10.1136/jnnp.20.4.302
- 10.1109/TBME.1968.4502530 · DOI
- bendat, 1966, Measurement and Analysis of Random Data
- blackman, 1958, The Measurement of Power Spectra from the Point of View of Communications Engineering
- jasper, 1966, The Thalamus
- lamarre, 1964, activitedes neuromes centraux chex le singe porteur d'un tremblement postural experimental, J Physiol, 56, 5 89
- albe-fessard, 1963, activites electriques caracteristiques de quelques structures cerebrales chez l'homme, Ann Chir, 17, 1185
- 10.1001/archneur.1968.00470350101009 · doi:10.1001/archneur.1968.00470350101009
- 10.1109/TBME.1973.324248 · DOI
- alberts, 1965, physiologic mechanisms of tremor and rigidity in parkinsonism, Confin Neurolog, 26, 318, 10.1159/000104047 · DOI
- boshes, 1966, measurement of tremor, J Neurosurg, 23, 324
- 10.1212/WNL.21.1.78 · DOI
- 10.1016/0013-4694(69)90037-6 · DOI
- 10.3171/jns.1963.20.1.0021 · doi:10.3171/jns.1963.20.1.0021
- 10.1001/archneur.1961.00450070068008 · doi:10.1001/archneur.1961.00450070068008
- 10.1212/WNL.10.9.805 · doi:10.1212/wnl.10.9.805
- 10.1113/jphysiol.1956.sp005668 · DOI · Paper page
Cited by
Fluctuations of disability in Parkinson's disease – clinical aspects
Marsden, C. D., Parkes, J. D., & Quinn, N. (1981) · Movement Disorders · doi:10.1016/b978-0-407-02295-9.50012-6 · Cited by 284
Optimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56
van Someren, E. J. W., van Gool, W. A., Vonk, B. F. M., Mirmiran, M., Speelman, J. D., Bosch, D. A., & Swaab, D. F. (1993) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(93)90148-r · Cited by 56
Adaptive band-pass filter (ABPF) for tremor extraction from inertial sensor data
Popović, L. Z., Šekara, T. B., & Popović, M. B. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.03.018 · Cited by 29
The application of video image processing to quantitative analysis of extremity tremor in humans
Świder, M. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00111-3 · Cited by 11
Metadata
- Authors
- Ackmann, J. J., Sances, A., Larson, S. J., & Baker, J. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1977-01
- Volume
- BME-24
- Issue
- 1
- Pages
- 49-56
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2078541979
- Cited by
- 29
- References
- 0
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.