The DOI matches its Crossref record.
Limited Lead Selection for Estimation of Body Surface Potential Maps in Electrocardiography
Abstract
Body surface potential mapping has shown promise as a technique to improve the resolution and accuracy of diagnostic electrocardiography, but the cost and effort required to obtain maps have made wide spread use impractical. As a step toward a practical system, the problems of redundancy and uniqueness of electrocardiographic signal information contained in large numbers of leads were investigated. An algorithm for optimal selection of a limited number of leads was developed. Data obtained from 132 human subjects including some with normal electrocardiograms (ECG) as well as some with abnormal ECGs, were used in the study. Estimation of body surface potentials from limited leads was evaluated using three criteria, including rms error, mean correlation coefficient between limited lead and total lead maps, and error to signal power ratio. Using 30 leads the average rms error was 32 μV, average correlation coefficient was .983 and noise to signal power was 3.5% in the presence of 20 μV rms noise. Another finding was that optimal sites are not unique, i.e., different sets of optimal sites may be found which perform equally well. This result has practical implications for the design of lead systems for estimating maps on the critically ill and on patients undergoing stress tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A New Data-Reduction Algorithm for Real-Time ECG Analysis
Abenstein, J. P., & Tompkins, W. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324962 · Cited by 269
Optimal magnetic sensor vests for cardiac source imaging
Lau, S., Petković, B., & Haueisen, J. (2016) · Sensors · doi:10.3390/s16060754 · Cited by 17
“This quantity is a comparable to previous MCG studies [50–52] and ECG studies [43,45,46].”
BackgroundResult
Metadata
- Authors
- Lux, R. L., Smith, C. R., Wyatt, R. F., & Abildskov, J. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1978-05
- Volume
- BME-25
- Issue
- 3
- Pages
- 270-276
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2009167204
- Cited by
- 216
- References
- 0
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.