Cited by 126Muscle activation and electromyography studiesECG Monitoring and AnalysisControl Systems and Identification

Myoelectric signal processing: Optimal estimation applied to electromyography—Part II: Experimental demonstration of optimal myoprocessor performance

Hogan, Neville, Mann, Robert W.·1980·IEEE Transactions on Biomedical Engineering

Abstract

This paper (Part II of two) presents an experimental demonstration of the performance achieved by implementing the mathematically derived optimal myoprocessor described in Part I. Almost an order-of-magnitude improvement over the common myoprocessor is obtained. Excellent agreement of the experimental results with the analytical predictions verifies the mathematical analysis. The relative contributions of each stage of the optimal myoprocessor are examined. A discussion and comparison of several existing and proposed techniques for myoprocessor improvement are presented.

Integrity signals

Registry

Crossref · 10.1109/tbme.1980.326653

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Hogan, N., & Mann, R. W.
Affiliations
Massachusetts Institute of Technology (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1980-07
Volume
BME-27
Issue
7
Pages
396-410
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2124211208
Cited by
126
References
0
Citations by year
2024: 2 · 2023: 4 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 3 · 2016: 7 · 2015: 4 · 2014: 2 · 2013: 4 · 2012: 3
FWCI
2.24
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
Keywords
myoelectric signal processing, electromyography, signal denoising
MeSH terms
Amputees, Electric Stimulation, Electromyography, Humans, Muscles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review